HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 64
FABRIC-RECONFIG, Recommended Action, Severity, Probable Cause
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
New Diagnostic and System Error Messages Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical FABRIC-RECONFIG Message Switch: , Info FABRIC-RECONFIG, 4, fabric: Probable Cause The fabric has reconfigured due to an offline port. The reason can be one of the following: ■ Fabric Merge: Merging two fabrics. ■ Own ID Rcvd: A subordinate switch receives an EFP or EFP ACC that has a payload error, listing this switch as being the principal switch. ■ Fabric Segment: Principal port became segmented. ■ Offline: Principal port went offline. ■ Unconfirmed domain: Switch was not able to get a domain ID. RDI ACC was never received. ■ Rcv BF: Received Build Fabric (BF) command. ■ HA: At F2 State: According to the Fibre Channel Specification, F2 is defined as the principal switch selection. If a failover occurs at this time, the switch is forced to restart principal switch selection. ■ HA: No Upstream: After failover, the newly active fabric thinks it is subordinate, but there is no upstream. ■ HA: bad EFP resp: Received an invalid EFP response. ■ HA: RJT EFP resp: Received an EFP reject response in which this EFP was used for verifying the neighbor's domain list as part of fabric warm-start recovery. A reject occurs if the neighbor is reconfiguring or the neighbor's port is in a bad state. 64 Fabric OS 3.1.3a Release Notes