HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 49

DIAG-ERRSTAT (TRUNC), DIAG-INIT, For the SAN Switch 2/16, replace the motherboard FRU.

Page 49 highlights

New Diagnostic and System Error Messages DIAG-ERRSTAT (TRUNC) Message Critical DIAG-ERRSTAT (TRUNC), 1 Probable Cause The Port Error Statistics counter is nonzero, meaning that a "Truncated frame" error was detected when receiving frames. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. This message is generated by the portloopbacktest or spinsilk commands, if problems are found. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-INIT Message Critical DIAG-INIT, 1 Probable Cause Port failed to go active in the loopback mode requested. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. This message is generated by the crossporttest, portloopbacktest, or spinsilk commands, if problems are found. Fabric OS 3.1.3a Release Notes 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

New Diagnostic and System Error Messages
49
Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-ERRSTAT (TRUNC), 1
Probable Cause
The Port Error Statistics counter is nonzero, meaning that a “Truncated frame”
error was detected when receiving frames. This can be caused by a faulty cable or
deteriorated SFP. It can also indicate deeper problems in the motherboard or
ASIC. This message is generated by the
portloopbacktest
or
spinsilk
commands, if problems are found.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if
necessary.
If the problem persists:
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-INIT, 1
Probable Cause
Port failed to go active in the loopback mode requested. This can be caused by a
faulty cable or deteriorated SFP. It can also indicate deeper problems in the
motherboard or ASIC. This message is generated by the
crossporttest
,
portloopbacktest
, or
spinsilk
commands, if problems are found.
DIAG-ERRSTAT (TRUNC)
DIAG-INIT