HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 40
Diag-cmicksum, Diag-cmidata
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
New Diagnostic and System Error Messages DIAG-CMICKSUM Message Critical DIAG-CMICKSUM, 1 Probable Cause CMI message received failed. This usually indicates an ASIC or motherboard failure. This message is generated by the cmitest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMIDATA Message Critical DIAG-CMIDATA, 1 Probable Cause CMI data received did not match data transmitted. This usually indicates an ASIC or motherboard failure. This message is generated by the cmitest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical 40 Fabric OS 3.1.3a Release Notes