HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 39
DIAG-CMERRPTN, A port received the wrong CMEM error type. This usually indicates an ASIC
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
New Diagnostic and System Error Messages DIAG-CMERRPTN Message Critical DIAG-CMERRPTN, 1 Probable Cause Error detected at the wrong port. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMERRTYPE Message Critical DIAG-CMERRTYPE, 1 Probable Cause A port received the wrong CMEM error type. This usually indicates an ASIC failure. This message is generated by the centralmemorytest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical Fabric OS 3.1.3a Release Notes 39