HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 68
SEC-SECCHANGE, Recommended Action, Severity, Probable Cause
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
New Diagnostic and System Error Messages Recommended Action No action is required. Severity Information SEC-SECCHANGE Message Info SEC-SECCHANGE, 4, text message Probable Cause A major security event has occurred. This message is for information purposes only, but you should verify that the event was planned. The text messages for individual events are: ■ secModeEnable: Secure mode has been enabled. ■ secModeDisable: Secure mode has been disabled. ■ secPolicyActivate: A, B, C policies have been changed. (A, B, C are names for changed policies.) ■ secVersionReset: Secure fabric version stamp has been reset. ■ secFCSFailover: The primary FCS has failed over to a new switch. ■ All password changes: A, B, C account passwords have been changed. (A, B, C are account names for which passwords are changed.) ■ configDownload: A configdownload process has been executed that changed the security policy database. ■ secPolicySave: A change to the security policy database has been saved. ■ SNMP community string change: The admin has made a change to the SNMP community strings. Recommended Action Verify that the security event was planned. If the security event was planned, no action is required. 68 Fabric OS 3.1.3a Release Notes