HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 54
DIAG-MEMORY, Memory size to be tested is less than or equal to zero. This usually indicates
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
New Diagnostic and System Error Messages DIAG-MEMORY Message Critical DIAG-MEMORY, 1 Probable Cause Data read from RAM location did not match previously written data into the same location. This usually indicates a CPU RAM failure. This message is generated by the ramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-MEMSZ Message Critical DIAG-MEMSZ, 1 Probable Cause Memory size to be tested is less than or equal to zero. This usually indicates a motherboard failure. This message is generated by the ramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical 54 Fabric OS 3.1.3a Release Notes