HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 62

DIAG-TBRAM_INC_RWTEST, ASIC internal registers failed write operation. This usually indicates an ASIC

Page 62 highlights

New Diagnostic and System Error Messages DIAG-TBRAM_INC_RWTEST Message Critical DIAG-TBRAM_INC_RWTEST, 1 Probable Cause ASIC internal registers failed read-modify-write operation. This usually indicates an ASIC failure. This message is generated by the turboramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-TBRAM_INC_WTEST Message Critical DIAG-TBRAM_INC_WTEST, 1 Probable Cause ASIC internal registers failed write operation. This usually indicates an ASIC failure. This message is generated by the turboramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical 62 Fabric OS 3.1.3a Release Notes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

New Diagnostic and System Error Messages
62
Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-TBRAM_INC_RWTEST, 1
Probable Cause
ASIC internal registers failed read-modify-write operation. This usually indicates
an ASIC failure. This message is generated by the
turboramtest
command, if
problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-TBRAM_INC_WTEST, 1
Probable Cause
ASIC internal registers failed write operation. This usually indicates an ASIC
failure. This message is generated by the
turboramtest
command, if problems
are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-TBRAM_INC_RWTEST