HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 62
DIAG-TBRAM_INC_RWTEST, ASIC internal registers failed write operation. This usually indicates an ASIC
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
New Diagnostic and System Error Messages DIAG-TBRAM_INC_RWTEST Message Critical DIAG-TBRAM_INC_RWTEST, 1 Probable Cause ASIC internal registers failed read-modify-write operation. This usually indicates an ASIC failure. This message is generated by the turboramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-TBRAM_INC_WTEST Message Critical DIAG-TBRAM_INC_WTEST, 1 Probable Cause ASIC internal registers failed write operation. This usually indicates an ASIC failure. This message is generated by the turboramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical 62 Fabric OS 3.1.3a Release Notes