HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 65
HA: Can't Snd EFP: Was not able to send an EFP., Principal Selection Mode: User has run
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
New Diagnostic and System Error Messages ■ HA: DLST EFP resp: Received an EFP accept response with a different domain list. ■ HA: PPRI EFP resp: Received an EFP accept response in which the response has a different principal switch priority number. ■ HA: PWWN EFP resp: Received an EFP accept response in which the response has a different principal switch World Wide Name. ■ HA: MAX EFP resp: An EFP to a neighbor failed to respond, and the fabric reached its maximum retry count for this neighboring switch. ■ HA: Can't Snd EFP: Was not able to send an EFP. ■ HA: Offline: A principal port went offline during fabric daemon's warm-start recovery. ■ Principal Selection Mode: User has run the fabricprincipal command, forcing a fabric rebuild. ■ D-list conflict: The principal switch received a domain list with domains additional to what the principal switch has already assigned, and the payload has the Pprincipal WWN and P\principal P\priority number as the principal switch. Recommended Action If the reconfiguration was unplanned, check for problems with the specified port. Some troubleshooting tasks include: Verify that the port was not disabled, using the portshow command. Verify that the port is cabled correctly. Verify that the SFP has not deteriorated. Severity Information Fabric OS 3.1.3a Release Notes 65