HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 41

Diag-cmiinvcap, Diag-cminocap

Page 41 highlights

New Diagnostic and System Error Messages DIAG-CMIINVCAP Message Critical DIAG-CMIINVCAP, 1 Probable Cause Unintended ASIC erroneously received a CMI capture flag. This usually indicates an ASIC or motherboard failure. This message is generated by the cmitest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CMINOCAP Message Critical DIAG-CMINOCAP, 1 Probable Cause CMI intended receiver ASIC failed to get CMI capture flag. This usually indicates an ASIC or motherboard failure. This message is generated by the cmitest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical Fabric OS 3.1.3a Release Notes 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

New Diagnostic and System Error Messages
41
Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-CMIINVCAP, 1
Probable Cause
Unintended ASIC erroneously received a CMI capture flag. This usually indicates
an ASIC or motherboard failure. This message is generated by the
cmitest
command, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-CMINOCAP, 1
Probable Cause
CMI intended receiver ASIC failed to get CMI capture flag. This usually indicates
an ASIC or motherboard failure. This message is generated by the
cmitest
command, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-CMIINVCAP