SEC-PIDCHGERR, PID Change failed: Change Area failed
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
New Diagnostic and System Error Messages SEC-PIDCHGERR, PID Change failed: Change Area failed Message Switch: , Error SEC-PIDCHGERR, 2, PID Change failed: Change Area failed. Probable Cause Either the defined or active policy could not be updated. If the policy database is very large, it might not be able to change the area because the new policy database exceeds the maximum size. This message can also be caused when the switch is short of memory. The value can be defined or active, or both policy sets were failed by the daemon. A negative value means that a policy set was failed by the daemon. Recommended Action Reduce the size of the policy database. Severity Error SEC-PIDCHGERR, PID Change failed: Size check failed Message Switch: , Error SEC-PIDCHGERR, 2, PID Change failed: Size check failed. Probable Cause Either the new defined or active policy was too large after modifying the area ID. The value can be defined or active, or both policy sets were failed by the daemon. A negative value means that a policy set was failed by the daemon. Recommended Action Reduce the size of the specified policy database. 66 Fabric OS 3.1.3a Release Notes