DIAG-CAMSID, For the SAN Switch 2/8, you must replace the entire switch.
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
New Diagnostic and System Error Messages This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. This message is generated by the camtest command. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-CAMSID Message Critical DIAG-CAMSID, 1 Probable Cause ASIC failed SID NO translation test. This usually indicates an ASIC failure. This message is generated by the camtest command. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical 36 Fabric OS 3.1.3a Release Notes