HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 63
Diag-timeout, Diag-xmit
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
New Diagnostic and System Error Messages DIAG-TIMEOUT Message Critical DIAG-TIMEOUT, 1 Probable Cause For portloopbacktest and crossporttest: Port failed to receive frame within timeout period. For centralmemorytest: Port failed to detect an interrupt within the timeout period. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-XMIT Message Critical DIAG-XMIT, 1 Probable Cause Port failed to transmit frame. This usually indicates an ASIC failure. This message is generated by the camtest, portloopbacktest, or spinsilk commands, if problems are found. Fabric OS 3.1.3a Release Notes 63