HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 53

Diag-lcmto, Diag-memnull

Page 53 highlights

New Diagnostic and System Error Messages DIAG-LCMTO Message Critical DIAG-LCMTO, 1 Probable Cause Central memory timeout: data transfer initiated did not complete within the timeout period. This usually indicates an ASIC failure. This message is generated by the centralmemorytest and the cmemretentiontest commands, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-MEMNULL Message Critical DIAG-MEMNULL, 1 Probable Cause The ASIC failed to allocate memory. This usually indicates a motherboard failure. This message is generated by the ramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical Fabric OS 3.1.3a Release Notes 53

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

New Diagnostic and System Error Messages
53
Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-LCMTO, 1
Probable Cause
Central memory timeout: data transfer initiated did not complete within the
timeout period. This usually indicates an ASIC failure. This message is generated
by the
centralmemorytest
and the
cmemretentiontest
commands, if
problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-MEMNULL, 1
Probable Cause
The ASIC failed to allocate memory. This usually indicates a motherboard failure.
This message is generated by the
ramtest
command, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
DIAG-LCMTO