Diag-lcmto, Diag-memnull
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
New Diagnostic and System Error Messages DIAG-LCMTO Message Critical DIAG-LCMTO, 1 Probable Cause Central memory timeout: data transfer initiated did not complete within the timeout period. This usually indicates an ASIC failure. This message is generated by the centralmemorytest and the cmemretentiontest commands, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-MEMNULL Message Critical DIAG-MEMNULL, 1 Probable Cause The ASIC failed to allocate memory. This usually indicates a motherboard failure. This message is generated by the ramtest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical Fabric OS 3.1.3a Release Notes 53