HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 58
Diag-portwrong, Diag-post_skipped
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
New Diagnostic and System Error Messages DIAG-PORTWRONG Message Critical DIAG-PORTWRONG, 1 Probable Cause Frame erroneously received by port M instead of the intended port N. This usually indicates an ASIC failure. This message is generated by the portloopbacktest command, if problems are found. Recommended Action For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-POST_SKIPPED Message Warning DIAG-POST_SKIPPED, 4 Probable Cause POST was not executed on the last boot up. Recommended Action This message is for information purposes only; no action is required. Severity Warning 58 Fabric OS 3.1.3a Release Notes
New Diagnostic and System Error Messages
58
Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-PORTWRONG, 1
Probable Cause
Frame erroneously received by port M instead of the intended port N. This usually
indicates an ASIC failure. This message is generated by the
portloopbacktest
command, if problems are found.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Warning DIAG-POST_SKIPPED, 4
Probable Cause
POST was not executed on the last boot up.
Recommended Action
This message is for information purposes only; no action is required.
Severity
Warning
DIAG-PORTWRONG
DIAG-POST_SKIPPED