HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 18
signal loss, zation count
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Important Notes Table 3: Fabric Watch Default Settings (Continued) Class Class Area name Description Default Settings Fabric Optic Port Link failure count Monitors number of link failures Loss of synchronization count Monitors number of loss synchronization errors. Loss of signal count Monitors number of signal loss errors Primitive sequence protocol error Monitors number of primitive sequence errors Invalid transmission word Monitors number of invalid words transmitted Threshold Setting Unit Error(s) Time Base Low High Minute 1 5 Buffer 0 Unit Error(s) Time Base Minute Low 1 High 5 Buffer 0 Unit Error(s) Time Base Minute Low 1 High 5 Buffer 0 Unit Error(s) Time Base Minute Low 1 High 0 Buffer 0 Unit Error(s) Time Base Minute Low 1 High 5 Buffer 0 Alarm Setting Changed 0 Exceeded 0 Below 0 Above 1 In-between 0 Changed 0 Exceeded 0 Below 0 Above 1 In-between 0 Changed 0 Exceeded 0 Below 0 Above 1 In-between 0 Changed 0 Exceeded 0 Below 0 Above 1 In-between 0 Changed 0 Exceeded 0 Below 0 Above 1 In-between 0 Threshold State Informative Informative Normal Faulty Informative Informative Informative Normal Faulty Informative Informative Informative Normal Faulty Informative Informative Informative Normal Faulty Informative Informative Informative Normal Faulty Informative 18 Fabric OS 3.1.3a Release Notes