HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 43

Diag-data, Diag-errstat (2long

Page 43 highlights

New Diagnostic and System Error Messages DIAG-DATA Message Critical DIAG-DATA, 1 Probable Cause Payload received by port did not match payload transmitted. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. This message is generated by the crossporttest or portloopbacktest commands, if problems are found. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical DIAG-ERRSTAT (2LONG) Message Critical DIAG-ERRSTAT (2LONG), 1 Probable Cause The Port Error Statistics counter is nonzero, meaning that a "Frame too long" error was detected when receiving frames. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. This message is generated by the portloopbacktest or spinsilk commands, if problems are found. Fabric OS 3.1.3a Release Notes 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

New Diagnostic and System Error Messages
43
Fabric OS 3.1.3a Release Notes
Message
Critical DIAG-DATA, 1
Probable Cause
Payload received by port did not match payload transmitted. This can be caused
by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the
motherboard or ASIC. This message is generated by the
crossporttest
or
portloopbacktest
commands, if problems are found.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP.
If the problem persists:
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8, you must replace the entire switch.
Severity
Critical
Message
Critical DIAG-ERRSTAT (2LONG), 1
Probable Cause
The Port Error Statistics counter is nonzero, meaning that a “Frame too long”
error was detected when receiving frames. This can be caused by a faulty cable or
deteriorated SFP. It can also indicate deeper problems in the motherboard or
ASIC. This message is generated by the
portloopbacktest
or
spinsilk
commands, if problems are found.
DIAG-DATA
DIAG-ERRSTAT (2LONG)