HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 55
Diag-nosegment, Diag-portabsent
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
New Diagnostic and System Error Messages DIAG-NOSEGMENT Message Critical DIAG-NOSEGMENT, 1 Probable Cause Port failed to go into loopback mode. This message usually indicates improper cable connections. This message is generated by the spinsilk command, if problems are found. Recommended Action Verify cable connections. Reseat the SFPs and cables and then reexecute the test. Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. Severity Critical DIAG-PORTABSENT Message Critical DIAG-PORTABSENT, 1 Probable Cause Port is not present. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. This message is generated by the portloopbacktest or spinsilk commands. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Fabric OS 3.1.3a Release Notes 55