HP StorageWorks 2/16V HP StorageWorks Fabric OS V3.1.3A Release Notes (AA-RUQY - Page 57
DIAG-PORTSTOPPED, command, if problems are
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
New Diagnostic and System Error Messages Probable Cause Port is connected to itself (self-loopback). This port M-to-port-M connection is not allowed by the test. This message usually indicates improper cable connections. This message is generated by the spinsilk command, if problems are found. Recommended Action Reconnect port (M) to a different port (N) and reexecute the test. Severity Critical DIAG-PORTSTOPPED Message Critical DIAG-PORTSTOPPED, 1 Probable Cause Port is no longer transmitting, as indicated by the Number Of Frames Transmitted counter being stuck at N frames. This can be caused by a faulty cable or deteriorated SFP. It can also indicate deeper problems in the motherboard or ASIC. This message is generated by the spinsilk command, if problems are found. Recommended Action Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the problem persists: For the SAN Switch 2/16, replace the motherboard FRU. For the SAN Switch 2/8, you must replace the entire switch. Severity Critical Fabric OS 3.1.3a Release Notes 57