Non-critical error detected ie. fan failure, power, supply failure Double fault situation
View all HP rp5400 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 124 highlights
Troubleshooting Run/Attention/Fault LED States Run Attn Fault Description (Green) (Amber) (Red) State: Off Off On Boot failed OS not up and running, PDC has detected a failure that is preventing boot from occurring. Action: 1. Check chassis error logs 2. Read console messages for indications of problems ie. warnings from PDC This is an invalid indication. Check the server's LEDs Off Off Flashing and try again. State: Off Flashing Off No code is executing (PDC, OS or Diagnostics) Non-critical error detected (ie. fan failure, power supply failure) (Double fault situation) Action: Cannot execute PDC. If more than one processor installed, the problem is most likely a failed system board. If only one processor installed, problem could be either the processor or system board. Check chassis error logs to determine the source of non-critical error. 110 Chapter 6