HP rp5400 User Guide - HP rp5400 Family of Servers - Page 175

HotSwap Power Converter Fan Replacement, the electrical outlet in back of the housing.

Page 175 highlights

Removing and Replacing Components Individual Component Remove/Replace Instructions HotSwap Power Converter Fan Replacement The power to the server does not have to be off to remove or replace a HotSwap Power Converter fan. Fans numbered 6 and 7 are located in the rear of the server. To replace a fan into the server, perform the following steps: 1. Orient the fan assembly so that the electrical plug will connect, then grasp the extended screw-heads (or the fan grill) and gently push the fan assembly into its housing. The fan assembly plug will connect with the electrical outlet in back of the housing. 2. Tighten the captive T-15 screws located diagonally across the face of the fan (upper left, lower right sides). The following graphic shows where HotSwap Power Converter Fans are located. Chapter 7 161

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231

Chapter 7
Removing and Replacing Components
Individual Component Remove/Replace Instructions
161
HotSwap Power Converter Fan Replacement
The power to the server does not have to be off to remove or replace a HotSwap Power Converter fan. Fans
numbered 6 and 7 are located in the rear of the server.
To replace a fan into the server, perform the following steps:
1. Orient the fan assembly so that the electrical plug will connect, then grasp the extended screw-heads (or
the fan grill) and gently push the fan assembly into its housing. The fan assembly plug will connect with
the electrical outlet in back of the housing.
2. Tighten the captive T-15 screws located diagonally across the face of the fan (upper left, lower right sides).
The following graphic shows where HotSwap Power Converter Fans are located.