Skewing, Diagnostic Information 2-45
View all Lexmark Optra C manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 77 highlights
5045-001 Skewing FRU 1 Paper 2 Cassette 3 Excessive paper (manual) 4 Paper setting (cassette) 5 Paper setting 6 Cassette claw 7 Paper dust, trash Registration roller Action Is recommended paper being used? Advise the user to use recommended paper. Is the cassette set properly? Set it correctly. Is more paper place at the pickup slot than suggested? Advise the user not to set more than the suggested amount of paper. Is the paper set properly against the cassette? Set the paper correctly. Is the paper placed against the manual feeding tray abutment? Properly set the paper on the manual feeding tray. Is the cassette claw deformed? Replace the cassette claw. Is paper dust or trash collected at the registration roller or feed guide? Clean. If no, replace the cassette paper assembly. Diagnostic Information 2-45