Nikon VAA109EA User Manual - Page 138

Metering, Exposure range, Metering coupling, Exposure compensation, Auto-exposure lock, Auto

Page 138 highlights

Metering: 3D color matrix: Center-weighted: Spot: TTL full-aperture exposure metering system with three metering modes 3D color matrix metering using 1,005-pixel CCD supported when D-Type Nikkor lens is attached; with other lenses, color matrix metering using 1,005-pixel CCD is supported Greatest weight (75% of total) given to a circle in the center of the frame 8 mm in diameter Exposure determined by 4 mm circle in center of frame (approx. 2% of frame); when a CPU Nikkor lens is attached, any of the five focus areas can be used for spot metering Exposure range: At ISO 100, room temperature, and with f/1.4 lens, 0-20 EV (center-weighted and 3D color matrix metering) or 2-20 EV (spot metering) Metering coupling: Combined CPU and AI Exposure compensation: -5 to +5 EV in increments of 1/3 EV; exposure compensation indicator appears in viewfinder and top control panel Auto-exposure lock: Detected exposure locked when AE/AF lock button is pressed Auto bracketing: Two or three exposures with compensation in increments of 1/3, 1/2, or 1 EV Shutter: Speed: Combined electronic (CCD) and mechanical shutter 30-1/16,000 sec. (1/3 increments), long time exposure (bulb) Speedlight Sync contact: X-contact only; flash synchronization at shutter speeds of Flash control: 1/500 sec. or slower. (1) Automatic balanced fill-flash controlled by five-segment TTL multi-sensor with single-component IC. If SB-28DX Speedlight is combined with a D-Type AF-Nikkor lens, 3D multi-sensor balanced fill-flash for D1 is used. If the SB-28DX is combined with AI-P or AF Nikkor lens other than D-Type, multi-sensor balanced fill-flash for D1 is used. If the SB-28DX is combined with a non-CPU Nikkor lens, balanced TTL flash for the D1 can be used with center-weighted metering. (2) Auto aperture (AA) flash: supported with SB-28DX and CPU Nikkor lenses (3) Non-TTL auto flash: supported with SB-28, SB-27, and SB- 22s Speedlights Flash sync modes: Front curtain (normal) sync, red-eye reduction, red-eye reduc- tion with slow sync, slow sync, rear curtain Ready light: Lights when flash SB-28DX, SB-28, SB-27, or SB-22s is fully charged; blinks for three seconds after being fired at full output Accessory shoe: Standard ISO hot-shoe contact with safety lock Sync terminal: Standard JIS terminal with locking screw Self timer: Electronically controlled timer, duration 2-20 seconds Technical Notes: Specifications 125

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

125
Metering
:
TTL full-aperture exposure metering system with three meter-
ing modes
3D color matrix:
3D color matrix metering using 1,005-pixel CCD supported
when D-Type Nikkor lens is attached; with other lenses, color
matrix metering using 1,005-pixel CCD is supported
Center-weighted:
Greatest weight (75% of total) given to a circle in the center of
the frame 8 mm in diameter
Spot:
Exposure determined by 4
mm circle in center of frame (approx.
2% of frame); when a CPU Nikkor lens is attached, any of the
five focus areas can be used for spot metering
Exposure range
:
At ISO 100, room temperature, and with f/1.4 lens, 0–20 EV
(center-weighted and 3D color matrix metering) or 2–20 EV
(spot metering)
Metering coupling
:
Combined CPU and AI
Exposure compensation
:
–5 to +5 EV in increments of
1
/
3
EV; exposure compensation
indicator appears in viewfinder and top control panel
Auto-exposure lock
:
Detected exposure locked when AE/AF lock button is pressed
Auto bracketing
:
Two or three exposures with compensation in increments of
1
/
3
,
1
/
2
, or 1 EV
Shutter
:
Combined electronic (CCD) and mechanical shutter
Speed:
30–
1
/
16,000
sec. (
1
/
3
increments), long time exposure (
bulb
)
Speedlight
Sync contact:
X-contact only; flash synchronization at shutter speeds of
1
/
500
sec. or slower.
Flash control:
(1) Automatic balanced fill-flash controlled by five-segment TTL
multi-sensor with single-component IC.
If SB-28DX Speedlight
is combined with a D-Type AF-Nikkor lens, 3D multi-sensor
balanced fill-flash for D1 is used.
If the SB-28DX is combined
with AI-P or AF Nikkor lens other than D-Type, multi-sensor
balanced fill-flash for D1 is used.
If the SB-28DX is combined
with a non-CPU Nikkor lens, balanced TTL flash for the D1 can
be used with center-weighted metering.
(2) Auto aperture (AA) flash: supported with SB-28DX and CPU
Nikkor lenses
(3) Non-TTL auto flash: supported with SB-28, SB-27, and SB-
22s Speedlights
Flash sync modes:
Front curtain (normal) sync, red-eye reduction, red-eye reduc-
tion with slow sync, slow sync, rear curtain
Ready light:
Lights when flash SB-28DX, SB-28, SB-27, or SB-22s is fully
charged; blinks for three seconds after being fired at full output
Accessory shoe:
Standard ISO hot-shoe contact with safety lock
Sync terminal:
Standard JIS terminal with locking screw
Self timer
:
Electronically controlled timer, duration 2–20 seconds