Installing and Replacing Network Interface Cards and Accelerated Data Path ADP Services Modules

Page 52 highlights

4 Installing and Replacing Network Interface Cards and Accelerated Data Path (ADP) Services Modules 6. Gently pull the PMC carrier or ADP module out from the slot and place it on a suitable, grounded work surface. 00310a.2 Note You need to follow step 7 through step 13 only for NICs and not for ADP modules, as the ADP module and the carrier are provided as one unit. 7. Locate the bezel retaining screws, used to keep the NIC attached, on the underside of the PMC carrier. 8. Remove the two bezel retaining screws with a Phillips screwdriver. 00311 Note If you are installing a NIC in an unoccupied slot on the PMC carrier, remove the blank bezel that covers the slot and retain it for future use. Proceed to step 11. 52 IP1220 and IP1260 Security Platforms Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

4
Installing and Replacing Network Interface Cards and Accelerated Data Path (ADP) Services Modules
52
IP1220 and IP1260 Security Platforms Installation Guide
6.
Gently pull the PMC carrier or ADP module out from the slot and place it on a suitable,
grounded work surface.
Note
You need to follow
step 7
through
step 13
only for NICs and not for ADP modules, as the
ADP module and the carrier are provided as one unit.
7.
Locate the bezel retaining screws, used to keep the NIC attached, on the underside of the
PMC carrier.
8.
Remove the two bezel retaining screws with a Phillips screwdriver.
Note
If you are installing a NIC in an unoccupied slot on the PMC carrier, remove the blank
bezel that covers the slot and retain it for future use. Proceed to
step 11
.
00310a.2
00311