Oki ML490 Maintenance Manual - Page 105
No Yes, Replace Control Board., Replace Transformer Assy., Remedied?, Replace Power Supply Board.,
View all Oki ML490 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 105 highlights
No Yes Replace Control Board. Replace Transformer Assy. Remedied? No Yes End Replace Power Supply Board. Control Board CN2 20 1 Pin No. Signal 20 19 18 17 16 15 14 13 12 11 10 9 8 7 4 3 1 EP EL +50V +5V +12V -8V (0V) (0V) 42114101 Rev.1 105 /
42114101
Rev.1
105 /
No Yes
Replace Control Board.
Replace Transformer Assy.
Remedied?
No Yes
End
Replace Power Supply Board.
Control Board
CN2
20
1
Pin No.
20
19
18 17
16
15
14
13
12
11 10
9
8
7
4
3
1
Signal
+50V
EP
+5V
EL
+12V
-8V
(0V)
(0V)