Oki ML490 Maintenance Manual - Page 28

Stop Printing

Page 28 highlights

(4) Overheat alarm (a) Head overheat alarm The voltage of the output HTEMP signal of the thermistors, one of which is contained in the print head and the other in the SP/LF driver, is monitored by the A/D port of the MPU to control the voltage. Temp Stop Mode up Mode down 132°C 122°C 118°C Mode and print control • Mixing Image and Characters Mode 1 2 3 4 5 6 7 DUTY 100% 87% 30% 13% 9% 5% 0% PrintSpeed Pass Direction Stop Printing 100% 1 100% 1 100% 1 90% 1 80% 1 70% 1 Stop - --- Until restoration • Only Image Mode 1 2 3 4 5 6 7 DUTY 100% 87% 30% 13% 9% 5% 0% PrintSpeed Pass Direction Stop Printing 100% 1 85% 1 70% 2 55% 2 40% 2 30% 2 Stop - --- Until restoration • When the temperature is between122°C and 132°C, the mode switches sequentially to higher level. When the temperature falls below 118°C, the mode switches to lower level. • When the temperature exceeds 132°C, printing will stop. • When temperature gradient is steep, higher mode shall be specified directly. 42114101 Rev.1 28 /

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135

42114101
Rev.1
28 /
(4)
Overheat alarm
(a)
Head overheat alarm
The voltage of the output HTEMP signal of the thermistors, one of which is contained
in the print head and the other in the SP/LF driver, is monitored by the A/D port of
the MPU to control the voltage.
Mode and print control
Stop
Mode up
Mode down
Temp
132
°
C
122
°
C
118
°
C
• Mixing Image and Characters
• Only Image
When the temperature is between122
°
C and 132
°
C, the mode switches sequentially
to higher level. When the temperature falls below 118
°
C, the mode switches to lower
level.
When the temperature exceeds 132
°
C, printing will stop.
When temperature gradient is steep, higher mode shall be specified directly.
Mode
1
2
3
4
5
6
7
PrintSpeed
100%
100%
100%
90%
80%
70%
Stop
DUTY
100%
87%
30%
13%
9%
5%
0%
Pass
1
1
1
1
1
1
Direction
---
Stop Printing
Until restoration
Mode
1
2
3
4
5
6
7
PrintSpeed
100%
85%
70%
55%
40%
30%
Stop
DUTY
100%
87%
30%
13%
9%
5%
0%
Pass
1
1
2
2
2
2
Direction
---
Stop Printing
Until restoration