Page 86 highlights
No. Item 4-5-1 Ribbon feed Specification Drawing Ribbon feeding Adjustment method To confirm: Ribbon shall be fed smoothly when the carriage is moved from side to side. 4-5-2 Running load to spac- 250g or less ing mechanism without a rib- bon cartridge To confirm: Ribbon Load measurement portion Make sure that the power is turned off at the time of measurement. Ribbon cartridge 42114101 Rev.1 86 /
42114101
Rev.1
86 /
Item
No.
Specification
Drawing
Adjustment method
Ribbon feed
4–5–1
To confirm:
Ribbon shall be fed
smoothly when the
carriage is moved
from side to side.
Running load to spac-
ing mechanism
4–5–2
To confirm:
Make sure that the
power is turned off at
the time of measure-
ment.
250g or less
without a rib-
bon cartridge
Ribbon
cartridge
Load
measurement
portion
Ribbon
Ribbon feeding