Compaq D51s Troubleshooting Guide - Page 61
Run the Drive Protection, using Windows NT 4.0
UPC - 890552632367
View all Compaq D51s manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
Post Error Messages Numeric Codes and Text Messages Code/Message 1721-SMART SCSI Hard Drive Detects Imminent Failure Beeps None Probable Cause Hard drive is about to fail. (Some hard drives have a firmware patch that will fix an erroneous error message). 1782-Disk None Controller Failure Hard drive circuitry error. 1800-Temperature Alert None Internal temperature exceeds specification. Recommended Action 1. Determine if hard drive is giving correct error message. 2. Apply firmware patch if applicable. 3. Back up contents and replace hard drive. 1. Run Computer Setup. 2. Clear CMOS. 3. Check cable seating/jumper settings. 4. Run hard drive diagnostics. 5. Disconnect additional drives. 6. Run the Drive Protection System test if available. 7. Check www.compaq.com/ support/techpubs/ customer_advisories/ for possible changes when using Windows NT 4.0 Service Pack 4. 8. Replace the hard drive. 9. Replace the system board. 1. Check that computer air vents are not blocked and cooling fan is running. 2. Verify processor speed selection. 3. Replace the processor. 4. Replace the system board. Troubleshooting Guide A-11