- Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 1
ProLiant 5500 Setup and Installation Guide For Intel Pentium II Xeon Processor-based Servers First Edition (July 1998) Part Number 328470-001 Compaq Computer Corporation - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 2
Compaq Computer Corporation. © 1998 Compaq Computer Corporation. All rights reserved. Printed in the U.S.A. The software described in this guide , SoftPaq, QuickBlank, QuickLock are trademarks and/or service marks of Compaq Computer Corporation. Microsoft, MS-DOS, Windows, and Part Number 328470-001 - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 3
...1-1 Processor ...1-1 System Memory ...1-2 Expansion Slots...1-2 Media Bays...1-2 SCSI ...1-3 Video ...1-3 Supported Interfaces ...1-3 ROM...1-3 Fans ...1-4 Power Supply ...1-4 High-Availability Features 1-4 System Management ...1-4 Compaq ProLiant 5500 Servers Setup and Installation Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 4
Support Software 1-5 Disk Drive Fault Tolerance 1-6 Compaq Insight Manager 1-6 Automatic Server Recovery-2 (ASR2 1-8 Security Features ...1-8 Compaq Integrated Remote Console 1-9 Compaq Integrated Management Display 1-10 Supported ...3-4 Optional Installation Service 3-4 Locating Materials - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 5
Using Compaq SmartStart...5-1 Compaq System Configuration Utility 5-3 Installing an Operating System 5-3 SMP Operating System Support 5-4 Loading Compaq Device Idle Screen Text ...6-5 Custom Menu Item...6-6 Custom Menu Screen ...6-6 Compaq ProLiant 5500 Servers Setup and Installation Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 6
vi Integrated Management Display continued Server Information ...6-6 Administrator Information 6-7 Service Information...6-8 Standard Display Fields ...6-9 Events ...6-9 ROM Date ...6-9 Bootblock Date: ...6-9 Memory ...6-9 Processor Configuration...6-9 F1 Prompt...6-9 Contrast ...6-10 Navigating - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 7
Label ...A-5 Laser Information...A-5 Battery Replacement Notice...A-5 Appendix B Electrostatic Discharge Grounding Methods...B-1 Appendix C Power Cord Set Requirements General Requirements ...C-1 Country-Specific Requirements C-2 Index Compaq ProLiant 5500 Servers Setup and Installation Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 8
- Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 9
, troubleshooting, and future upgrades. IMPORTANT: These instructions are for use with Intel Pentium II Xeon processor-based servers only. The power supplies in this computer system produce hazardous energy levels. The guide is for the person who installs, administers, and repairs servers. Compaq - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 10
s Compaq ProLiant 5500 Setup and Installation Guide s Compaq Servers Troubleshooting Guide s Integrated Remote Console Guide Installing Insert the CD into the CD-ROM drive. 2. From the Windows Program Manager, select File and then Run. 3. Type :\SETUP and select OK; where is the - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 11
icon will be created in your system. You must leave the CD in the CD-ROM drive to access the documentation. IMPORTANT: These installation instructions are for the ProLiant 5500, Intel Pentium II Xeon processor-based server documentation only. Compaq ProLiant 5500 Servers Setup and Installation Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 12
for operation and future Instructions for installing and using the Integrated Remote Console. Steps for diagnosing and resolving common server Compaq ProLiant 5500 Setup and Installation Guide Integrated Remote Console Guide Compaq Servers Troubleshooting Guide Setup and Install Integrated - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 13
. Printing the Documentation Once you open a document, you can print the entire document or a single page: 1. From the Acrobat Reader menu bar, select File. 2. Select Print. 3. Use Print Range to select what you want to print. 4. Select OK. Compaq ProLiant 5500 Servers Setup and Installation Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 14
CDs A set of printed documents on the CD is available. The set contains: s Compaq ProLiant 5500 Setup and Installation Guide s Compaq Integrated Remote Console Guide s Compaq Servers Troubleshooting Guide You may also order additional copies of the Server Documentation CD. NOTE: The printed - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 15
in uppercase. FILENAMES File names appear in instructed to type information, type the information without pressing the Enter key. Enter When you are instructed to enter information, type the information and then press the Enter key. Compaq ProLiant 5500 Servers Setup and Installation Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 16
found in the text of this guide. They have the following meanings. IMPORTANT: Presents clarifying information or specific instructions. NOTE: Presents commentary, sidelights, or of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce risk of injury from - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 17
lb (41.8 kg.). If the unit is to be loaded above chest level, a third person must assist in aligning the rails while the other two support the unit. Compaq ProLiant 5500 Servers Setup and Installation Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 18
by-step instructions for installation, and as a reference for operation, troubleshooting, and future upgrades. Getting Help If you have a problem and have exhausted the information in this guide, you can get further information and other help in the following locations. Compaq Website The Compaq Web - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 19
In Canada, call 1-800-263-5868 For Compaq technical support: In the United States and Canada, call 1-800-386-2172 For Compaq technical support phone numbers outside the United States and Canada, visit the Compaq Web Site at: //www.compaq.com. Compaq ProLiant 5500 Servers Setup and Installation Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 20
unless otherwise noted. Processor Compaq ProLiant 5500 servers support up to four Intel Pentium II Xeon processors with corresponding processor power modules and support for future Intel Pentium II Xeon processors. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 21
256 MB DIMMs) s Supports up to 4 memory banks; each bank consists of 4 DIMMs. One bank is installed or removed at a time. Each bank must have four DIMMs of the same size and speed. Expansion Slots Seven I/O expansion slots: s Six 32-bit PCI slots (one is populated with a Compaq Netelligent 10/100 TX - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 22
The following optional controller boards are currently supported (see www.compaq.com for updates on device support) t Smart Array 3200 Controller t diagnostics s ROMPaq Utility used to upgrade ROM Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 23
correction fault tolerance options. s The Rapid Recovery Services provides fast identification and resolution of complex faults. Highlights include: Integrated Management Logs, Automatic Server Recovery-2 (ASR-2), and Compaq Integrated Remote Console. s Integrated Management Display (IMD) offers a - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 24
an extensive set of features and optional tools to support effective server management and configuration. These features are described in this guide: s SmartStart and Support Software CD s Fault Tolerance s Compaq Insight Manager s Automatic Server Recovery-2 (ASR-2) s Integrated Management Display - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 25
Tolerance Disk drive fault tolerance for Compaq servers is covered in more detail in the Compaq Server Online Reference Guide on the Systems Reference Library (SRL) CD. The following Redundant Array of Inexpensive Disks (RAID) types are supported: s RAID 0 - no fault tolerance s RAID 1 - mirroring - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 26
that may require action. s Alarm forwarding supports the forwarding of short text messages to Mobile Communication (GSM/Short Messaging Service (SMS). s Broad configuration Utilities," for more information. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 27
protected power switch s Serial/parallel interface control s Remote access password s Front bezel lock (tower model only) Refer to the Compaq Server Online Reference Guide on the Systems Reference Library (SRL) CD for more information on these security features. For use with Intel Pentium II Xeon - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 28
equipped with an optional supported modem, you can perform a wide range of configuration activities using the standard Compaq Integrated Remote Console (IRC Integrated Remote Console Guide included on the Documentation CD. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 29
Compaq Integrated Management Display The Integrated Management Display (IMD) is an LCD display panel that assists you in diagnosing and servicing the Management Display rotates to support both tower and rack configurations. s Manageability - Typical service and administrative information displayed - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 30
in servicing computer equipment and in dealing with products capable of producing hazardous energy levels. WARNING: Care must be exercised when the hood or side covers are removed because the system does not shut down automatically. Compaq ProLiant 5500 Servers Setup and Installation Guide For - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 31
1-12 Introduction IMPORTANT: This server is not equipped with chassis interlocks. There are board interlocks that connect the memory board, processors, peripheral board and power switch cable into one interlock chain. When one of the connected components in the interlock chain is improperly seated - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 32
from Compaq is available through an Authorized Compaq Reseller. Supported components on-screen instructions or contact an Authorized Compaq Service Provider in Compaq recommends that you replace a component that is in a prefailure condition. Compaq ProLiant 5500 Servers Setup and Installation Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 33
2 Installation Overview This chapter presents an overview of the installation and configuration procedure for Compaq ProLiant 5500 servers. You are referred to later chapters in this guide for detailed discussions of rack installation, hardware option installation, and configuration. Topics in this - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 34
This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure. CAUTION: The Compaq ProLiant Server must always be operated with the system unit cover on. Proper cooling will not be achieved if the system unit cover is - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 35
discusses the power, grounding, and temperature requirements of the Compaq ProLiant 5500 server. Power Requirements WARNING: To reduce the risk Data Processing Equipment (NFPA-75, 1992). Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 36
To ensure continued safe and reliable operation of the equipment, locate the system in a well-ventilated, climate-controlled environment. The Compaq Maximum Recommended Ambient Operating Temperature (TMRA) for most server products is 35°C (95°F). Therefore, the temperature in the room where - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 37
server. Each procedure is a summary of the steps you will follow to install your Compaq ProLiant 5500 server. Detailed instructions for each of the general steps are included in later chapters of this guide. Installing a Rack Mount Model Below are the general steps for installing your rack-mountable - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 38
Support Software package. After the SmartStart and Support Software program has finished configuring your system, you have completed the installation of your new Compaq model. See Chapter 4 and the options kits for detailed instructions on installing other options and components. s Set switches: - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 39
card included in your SmartStart and Support Software package. After the SmartStart and Support Software program has finished configuring your system, you have completed the installation of your new Compaq server. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 40
Compaq's optional installation service to install your rack products. See "Optional Installation Service instructions to protect Compaq Installing Rack Products CD" for the rules that govern the vertical placement of rack-mounted servers. Compaq ProLiant 5500 Servers Setup and Installation Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 41
lb (41.8 kg). If the unit is to be loaded above chest level, a third person must assist in aligning the rails while the other two support the unit. CAUTION: Do not place anything on power cords or cables. Arrange them so that no one may accidentally step or trip over them - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 42
3-3 Airflow Requirements Compaq ProLiant rackmount servers draw cool air in through the front door and and across the servers. These gaps should be covered with blanking panels. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 43
will make all of the arrangements to have the rack system installed by qualified Guaranteed Service Providers. An order form with pricing is available from PaqFax, the Compaq fax retrieval service. Call 1-800-345-1518, select PaqFax, and request Document No. 4552. Installation may also be ordered - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 44
install the ProLiant 5500 server in the rack is included with the rack and with the server. 2 1 3 4 5 6 7 8 Figure 3-1. Rack mounting hardware included with the server Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 45
for proper attachment of the rack mounting brackets s Documentation and software t Server Setup and Management Package t Compaq Installing Rack Products CD t CompaqCare folder t Compaq Product Quality Statements t Owner's Registration folder For use with Intel Pentium II Xeon processor-based servers - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 46
CD and the Rack Information Library CD can be found on the web on the Compaq website at www. compaq.com. The entire Rack Resource CD Kit PN 298721-001 ships with all Compaq racks and can be ordered through a Compaq authorized reseller. A summary of the content of each CD follows: s Rack Builder - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 47
t Redundant fans Preparing the Mounting Brackets and Slide Rail Assemblies Each pair of mounting brackets, with attached slide rail assemblies supports one rack-mountable server. Figure 3-2. Rack mounting brackets; alignment tabs identify the front flanges Each slide rail assembly consists of - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 48
until the server rail release latch clicks. Holding down the latch, slip this piece out of each bracket rail, as shown in the following figure. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 49
3-10 Rack-Mount Server Installation Figure 3-4. Removing the server rail from the bracket rail 2. Put the server rails to one side. You will attach them to the rack server chassis later, in the section, "Attaching Server Rails." The next figure shows the separated bracket rail with its inner sliding - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 50
the mounting bracket has alignment tabs on its flange. t The front of the bracket rail allows the inner slide to move forward on ball bearings. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 51
along one edge of the mounting bracket. These marks identify the mounting holes for the 26-inch slides used in Compaq racks. (The other markings stamped along the opposite edge are for use with slides that support other servers.) For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 52
steps 4 through 7 with the other bracket rail and mounting bracket. You now have a pair of mounting bracket slide assemblies to be attached to the rack. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 53
rack leveling feet are extended to the floor and support the full weight of the rack. Each rack Rack Planning and Installation Guide included on the "Compaq Installing Rack Products CD" installation of the server. See illustrations and instructions printed on the template. IMPORTANT: Determine the - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 54
the thumbscrews through the server's face plate. Be sure to follow the alignment instructions on the template, and keep the sides of the template squared up with the proper alignment. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 55
3-16 Rack-Mount Server Installation Figure 3-8. Measuring with the template 3. After marking the front of the rack, flip the template over and mark the back rails of the rack. Open the rear door of the rack to access the back rails. 4. On the back of the rack, also mark the rail to show the top of - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 56
bracket help to align it with the front of the rack frame. Cage nuts are not used for the front attachment of the mounting bracket. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 57
of the rack first, using one M6 x 1.0-12L Phillips screw in the bottom hole of the bracket. Do not use the washers supplied with the Compaq rack. IMPORTANT: Use only the bottom hole of the bracket as shown in Figure 3-10. Figure 3-10. Attaching mounting bracket assembly to the front of - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 58
back of mounting bracket assembly installed 4. After attaching both of the mounting bracket assemblies to the rack, prepare the server for mounting in the rack. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 59
3-20 Rack-Mount Server Installation Attaching Server Rails 1. Place the tab on a server rail at the front of the server chassis. The holes in the server rail will line up only one way with the chassis. 2. Attach the flat side of a server rail to each side of the server chassis with four 8-32 x 1/4- - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 60
server with two 6-32 x 1/4 Phillips screws. 2. Attach the rack rail covers to the rack. Figure 3-13. Attaching a cable management arm server bracket to the server Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 61
lb (41.8 kg). If the unit is to be loaded above chest level, a third person must assist in aligning the rails while the other two support the unit. IMPORTANT: To make the server lighter and more manageable, do not install drives in the server until after you load the server into - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 62
server rails into the slide rails. Tilting the server up or down could result in damage to the rails. Figure 3-14. Loading the rack server Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 63
into the rack, you may have to apply some pressure. After the first time, the ball bearings in the slide will move easily. IMPORTANT: When servicing the server, fully extend the server until the latches lock. To return the server to the rack, depress the latches and slide the server into - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 64
retaining plate on the inside of the rack. Attach the arm to the rack with two 10-32 x 5/8-inch Phillips washer-face hex-head screws. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 65
3-26 Rack-Mount Server Installation Figure 3-16. Attaching the cable management arm to the rear brace of the rack 4. Attach and secure external cables for keyboard, mouse, monitor, network and power as shown in Figure 3-17. See Chapter 7, "Cabling," for external cabling connector locations. Figure - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 66
in the SCSI drive bay area. NOTE: The illustrations in this chapter may vary slightly depending on whether you have a tower model or rack model. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 67
, allow the internal system components to cool before touching. WARNING: Repair should be performed only by qualified Service Providers who are trained in servicing computer equipment and in dealing with products capable of producing hazardous energy levels. CAUTION: Electrostatic discharge can - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 68
the operating system in an orderly manner as directed in your operating system instructions. 3. Power down the server and remove the power cord(s). WARNING: the front of the server. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 69
4-4 Installing Hardware Components 7. Slide the side cover toward the rear of the unit about 1 inch (2.5 cm); then remove the cover. Figure 4-1. Removing the server cover Accessing the Processor The ProLiant 5500 server is shipped with one processor module and three terminator boards which fill all - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 70
4-2. Processor locations 2. Remove one of the terminator boards by turning the retaining knob counterclockwise, releasing the side tabs and pulling up as shown in Figure 4-3. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 71
4-6 Installing Hardware Components 2 2 1 3 Figure 4-3. Removing the terminator board 3. See Figure 4-4 below for processor installation procedure. 3 2 2 1 Figure 4-4. Installing the Intel Pentium II Xeon Processor 4. Install the processor power module (PPM) in the slot next to the processor as - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 72
4-7 4 3 2 1 Figure 4-5. Processor power module locations 2 2 1 Figure 4-6. Installing the processor power module Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 73
4-8 Installing Hardware Components Accessing DIMM Sockets on the Memory Board 1. Power down the server. 2. Remove the memory board as shown in Figure 4-7. 1 2 1 Figure 4-7. Removing the memory board For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 74
see the following section titled "Memory Banks." 2 1 2 Figure 4-8. Installing a DIMM 4. Install the memory board as shown in Figure 4-9. 2 1 2 Figure 4-9. Installing memory board Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 75
4-10 Installing Hardware Components Memory Banks In the Compaq ProLiant 5500 server, the Memory board is grouped into 4 banks where 1 bank is 2 DIMMs adjacent to 2 other DIMMs as shown below for bank 1. When memory - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 76
connector a IDE connector 9 - w Processor power module connectors s System board power connectors e-y Processor connectors d Core frequency switch u Floppy signal connector Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 77
4-12 Installing Hardware Components System Board Switches Your ProLiant 5500 server has been shipped with the core frequency switch properly set. However; you may consider changing the core frequency switch setting when upgrading to a faster processor. CAUTION: Data integrity may be compromised when - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 78
switch 12a Serial A connector 6 External battery connector 12b Video connector 7 SCSI Port 1 connector 13a Keyboard connector 8 SCSI Port 2 connector 13b Mouse connector Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 79
password is enabled Power on password is disabled 6. Maintenance * NV RAM is valid NV RAM is invalidated, configuration is lost NOTE: See the ProLiant 5500 Service and Maintenance Guide for information on the use of this switch. For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 80
not shut down automatically. Accessing the Drive Cage Back Plane These instructions cover the removal of the simplex drive cage and the installation of damage to hardware could result. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 81
4-16 Installing Hardware Components 2 1 Figure 4-13. Removing a fan 3. Unlock the server, open the front panel, and slide the front panel up and away from the server. Figure 4-14. Removing front panel 4. Loosen the thumbscrews on the front of the drive cage. 5. Pull out the latch at the back of the - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 82
. Drive cage latch 6. Remove all cables from the back of the drive cage except for the removable media power cable. 7. Completely remove the drive cage. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 83
backplane board must have a Duplex Enabler board installed in order for the SCSI bus to be terminated properly. If this board is not installed, the service LEDs of all drives will light as a warning. Figure 4-17. Installing the duplex drive cage For use with Intel Pentium II Xeon processor-based - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 84
1 2 3 4 5 Figure 4-18. Connectors on back of drive cage SCSI input 1 Duplex board power connector SCSI Input 0 Removable media power connector Duplex enabler board Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 85
4-20 Installing Hardware Components 4. Pull out the drive cage latch and push the drive cage back fully until the drive cage latch can be pushed into place. 5. Tighten the thumbscrews on the front of the drive cage. 6. Connect SCSI controller cables. See Chapter 7, "Cabling," for information on SCSI - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 86
. Accessing the Hot-Plug SCSI Drives 1 2 3 Figure 4-20. Removing a SCSI drive NOTE: Pinch both sides of drive levers to unlock, then swing the levers out. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 87
4-22 Installing Hardware Components 2 1 Figure 4-21. Installing a SCSI drive SCSI ID Numbers There are several possible numbering schemes depending on whether you are using 1-inch height drives, 1.6-inch height drives, or a simplex controller. The following figures illustrate the simplex mode - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 88
Supply Locks The ProLiant 5500 server chassis will support a padlock to lock the server's power supplies. This option is purchased separately by ordering the option kit part number 296956-002. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 89
install the SmartStart and Support Software CD: 1. With your computer turned on, locate the CD-ROM drive. 2. Open the CD-ROM tray by pressing the load/unload button. Figure 5-1. Installing a CD in the CD-ROM drive Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 90
Server Configuration and Utilities 3. Place the SmartStart and Support Software CD in the tray (label facing up), handling and Management pack shipped with your server. To manage the system, refer to the Compaq Management CD provided in the Server Setup and Management pack shipped with your server. - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 91
such as TEST and INSPECT Utilities Installing an Operating System Compaq ProLiant 5500 servers support the following operating systems: s Novell NetWare 4.11 and system CD or diskette. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 92
Customer Service to get a SmartStart pack with additional operating system support. Some operating systems have driver support/updates but not an integrated SmartStart installation. You can still configure your server and manually install your operating system. SMP Operating System Support Compaq - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 93
to get information about the operating system environment. For instructions on using the Diagnostics Utility and other Compaq utilities, refer to the Compaq Systems Reference Library CD. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 94
The Integrated Management Display rotates to support both tower and rack configurations. s second counts, it is important to have service and administrative information at your fingertips. Typical navigate through menus. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 95
Management Display Installing the IMD in the Tower Model The Integrated Management Display (IMD) feature is standard in rackmountable models of the Compaq ProLiant servers; this feature is optional in tower models. The following information explains how to install the IMD in the tower model - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 96
2 1 2 Figure 6-2. Installing the Integrated Management Display 4. Connect Integrated Management Display cable to the peripheral board. 5. Restore server to normal operation. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 97
Configuration Utility After installing the hardware, configure the Integrated Managment Display using the System Configuration Utility located on the Compaq SmartStart and Support Software CD. It is recommended that this version of System Configuration be used because it is the latest one that - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 98
After the display has been idle for five minutes, the Integrated Management Display shows the following default screen text: COMPAQ PROLIANT 5500 ESC Figure 6-3. Idle Screen text Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 99
Name Enter up to 2 lines of no more than 14 characters each. An example might be to name the server by department, such as: CUST SERVICE WESTERN REGION Primary Operating System Enter the primary operating system of the server, for example, NT4.0. Enter up to 3 lines of 14 characters each line - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 100
might be listing an additional administrator that serves as a backup to the primary administrator. Enter up to 2 lines of no more than 14 characters each. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 101
. Enter up to 2 lines of no more than 14 characters each. Other This is a user-defined field. Enter any additional service information. An example might be to enter service contract number. Enter up to 2 lines of no more than 14 characters each. For example, server history information could be - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 102
a keyboard or monitor. This feature is useful for service and diagnostic purposes, allowing the boot up process to continue without attaching a monitor and keyboard and their respective cables. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 103
and DOWN arrows. Press the UP arrow to increase the contrast, and press the DOWN arrow to decrease the contrast. Navigating the Menus The Compaq Integrated Management Display is menu-driven and easy to use. Information to navigate and utilize the menus follows. Normal Run-time Behavior When powering - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 104
lower right corner, indicates more information exists. Press the Down Arrow on the IMD to view the information. Press and hold the button to scroll. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 105
6-12 Integrated Management Display System Behavior with Error Events After system POST, if there is an F1 error condition the IMD flashes this message: LCD-013.EPS !ALERT! Press Any Key to View New Events ESC Figure 6-5. New event message At this point it is necessary to scroll through each - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 106
Operating System t Other s Administrator t Name t Phone t Pager t Other s Service t Name t Phone t Pager t Other s Custom Menu Item (if entered) s Processors Contrast s Contrast s Other Information Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 107
a non-fatal error condition. s Critical-indicates a component failure. The Integrated Management Log requires Compaq Operating Systemdependent drivers. Refer to Chapter 5, "Server Configuration and Utilities" for instructions on installing the appropriate drivers. For use with Intel Pentium II Xeon - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 108
Compaq Insight Manager s From within Compaq Survey Utility s Using the IML Management Utility, a DOS program located on the Compaq SmartStart and Support Software CD. Compaq Insight Manager Compaq instructions Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 109
Integrated Management Display Viewing the Event List 1. From Compaq Insight Manager, select the appropriate server; then the list from the Recovery/Integrated Management screen. To print the list, follow the instructions below. 4. If a failed component has been replaced, select the event from the - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 110
have opened the text file, you can print it using the print feature of the viewer. Compaq IML Management Utiltiy The Compaq IML Management Utility is print events from the IML. It is located on the Compaq SmartStart and Support Software CD. Refer to the SmartStart Installation for Servers poster - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 111
Manager, or from within the Compaq Survey Utility. An example of the format of an event as displayed on the Integrated Management Display is as follows: **001 of 010** ---CAUTION--03/19/1997 12:54 PM FAN INSERTED Main System Location: System Board Fan ID: 03 **END OF EVENT** Table 6-2 identifies - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 112
(Slot X, Socket X) Processor Uncorrectable internal error (Slot X, Socket X) Unrecoverable Host Bus Data Parity Error Unrecoverable Host Bus Address Parity Error Continued Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 113
Inserted Power Supply Removed Power Supply Not Redundant System Configuration Battery Low Power Module Failure Power Modules Not Redundant AC Voltage Problem Power AC Overload Event Message EISA Expansion Bus Master Timeout (Slot X) EISA Expansion Bus Slave Timeout EISA Expansion Board Error (Slot - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 114
] Automatic Operating System Shutdown Initiated Due to Fan Failure Automatic Operating System Shutdown Initiated Due to Overheat Condition Fatal Exception (Number X, Cause) Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 115
Code Messages Probable Cause Indicates a RAM test error Indicates a data bus error Indicates a data bus error Recommended Solution Contact Authorized Compaq Service Representative Check the cable connection Check the cable connection For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 116
32-inch, 3-device terminated SCSI cable to removable media bays (part number 199616-012) s One 8.75-inch, external loopback SCSI cable (part number 189646-005) Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 117
connectors. s External SCSI cables have a round wire with securable connectors. s Internal SCSI cables have a flat ribbon wire with push-on connectors. s Compaq SCSI cables are keyed so that they cannot be installed incorrectly. s Fast-Wide SCSI-2 (wide SCSI) internal ribbon cables are physically - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 118
SCSI) 68-Pin (Wide SCSI) 68-Pin External Fast-SCSI-2 (Standard SCSI) 50-Pin Figure 7-2. SCSI connectors Key Internal Fast-SCSI-2 (Standard SCSI) 50-Pin Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 119
7-4 Cabling External Cabling The following figure shows the locations of the external connectors on the back of the server. 12 3 4 5 6 7 12 11 10 9 8 Figure 7-3. External connectors 1 Parallel port connector 7 2 External SCSI connector 8 3 Serial A connector 9 4 Video connector : 5 SCSI - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 120
ProLiant 5500 servers. For the latest information on SCSI controllers and configurations supported on the Compaq ProLiant 5500 server, see the following URL: www.compaq.com. IDE Controller Compaq ProLiant 5500 servers ship standard with CD-ROM drives in the removable media bay. Figure 7-4 shows - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 121
7-6 Cabling Integrated SCSI Controller The Compaq ProLiant 5500 server has a Dual Channel Integrated Wide-Ultra SCSI-3 controller integrated into the peripheral board. The two outputs from this controller are designated SCSI - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 122
Input 0. This connector is shown in Figure 7-5. 1 2 3 Figure 7-5. Simplex board connectors Simplex board power connector SCSI Input 0 Removable media power connector Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 123
7-8 Cabling SCSI Input 0 Channel The SCSI Input 0 channel connects to SCSI hard drive slots 0 through 6, as shown in Figure 7-6. 3 2 1 4 5 3 2 6 1 6 5 0 4 Figure 7-6. SCSI input 0 channel SCSI Port 1 SCSI Port 2 Peripheral board System board SCSI Input 0 SCSI hard drives - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 124
3device terminated SCSI cable (199616-010) from SCSI Port 1 to the removable media bay s Use 50 to 68 pin adapter devices. (199618-001) if needed. s See note 1. Continued Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 125
the 22-inch 3-device terminated SCSI cable (199616-010) from SCSI Port 2 to the removable media bay devices. s Use 50 to 68 pin adapter (199618-001) if needed. s See note 1. 35/70 DLT Drive s Connect the 22-inch 3-device terminated SCSI cable (199616010) from SCSI Port 2 to the removable media bay - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 126
Kit #212055-001. Note 2: The SCSI Port 2 Controller is connected to the SCSI Port 2 connector and external SCSI connector. It is recommended that you use SCSI Port 2 controller for either internal or external drives, not both. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 127
, use the SCSI Cable Matrices in Tables 7-1 and 7-2 and these examples as a general guide. Example 1: Standard Configuration - Using Integrated SCSI Port 1 for Hard Drives, SCSI Port 2 for Removable Media Bay The Compaq ProLiant 5500 server ships standard in the simplex mode, as shown in Figures - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 128
13 SCSI Port 1 SCSI Port 2 Peripheral board System board SCSI Input 0 SCSI hard drives Simplex board Removable media bay Figure 7-8. Example 1: Connection diagram Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 129
7-14 Cabling Example 2: Using One Optional SMART-2 Controller for Hard Drives, Integrated SCSI Port 1 for Removable Media Bay 1. Remove the installed SCSI cable (199606-007) from Integrated SCSI Port 1 and SCSI Input 0 of simplex board. 2. Install the 19-inch point-to-point non-terminated SCSI cable - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 130
Port 2 Peripheral board Optional SCSI board System board SCSI Input 0 SCSI hard drives Simplex board Removable media bay Figure 7-10. Example 2: Connection diagram Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 131
mode split the hard drive backplane board (duplex board) into two separate independent SCSI channels. Each channel supports either 4 X 1" or 3 X 1.6" drives. Duplex SCSI Channels In the Compaq ProLiant 5500 server, the duplex board has two SCSI input channels, designated SCSI Input 0 and SCSI Input - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 132
must set the SCSI IDs for the devices in the removable media bay to 4, 5, or 6. 3 2 1 4 5 8 3 3 2 2 1 6 1 10 0 0 9 7 Figure 7-12. SCSI Input 0 and 1 channels Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 133
199616-010) from SCSI terminated SCSI PORT 1 to the removable cable (199606- media bay devices. 010) from SCSI s Use 50 to 68 pin adapter (199618-001) if needed. s See Note 2 PORT 1 to the removable media bay devices. For use with Intel Pentium II Xeon processor-based servers only Continued - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 134
2. 35/70 DLT Drive s Connect 22-inch 3-device terminated SCSI (199616-010) from duplex enabler board to the removable media bay devices. s See Note 2. continued Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 135
7-20 Cabling SCSI Cable Usage Matrix for Duplex Mode continued Controller 32 Bit FastWide SCSI-2 Controller /P and Wide-Ultra Controller/P Hot-Plug SCSI Hard Drives in Internal Drive Cage s Use cable option kit 306585-B21. s Connect 19-inch point-to-point nonterminated SCSI cable (199606007) from - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 136
SCSI port 1 or 2 of integrated SCSI controller to Input 1 of duplex board. 35/70 DLT Drive Tape Drives and CDROMs are not supported using a SMART-2 Array Controller Continued Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 137
Autoloader 8X SCSI CD-ROM 4/16 TurboDAT 15/30 DLT Drive Tape Drives and CDROMs are not supported using a SMART-2 Array Controller 35/70 DLT Drive Tape Drives and CDROMs are not supported using a SMART-2 Array Controller s Connect 19-inch point-to-point nonterminated SCSI cable (199606007) from the - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 138
is needed to connect to hard drive backplane SCSI inputs 0 or 1 to support duplex mode operation for this configuration. Note 2: SCSI PORT 2 output will not 7-2 and these examples as a general guide. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 139
7-24 Cabling Example 1: Using Integrated SCSI Port 1 and Port 2 for Hard Drives with SCSI Input 1 Connected to the Removable Media Bay 1. Install the Duplex Enabler Board on the back of the Drive Cage, if not already installed. 2. Connect 19-inch point-to-point non-terminated SCSI cable (199606007), - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 140
board System board SCSI Input 0 SCSI hard drives Duplex board SCSI Input 1 Duplex enabler board Removable media bay Figure 7-14. Example 1: Connection diagram Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 141
label indicating the interference potential of the device as well as additional operating instructions for the user. The rating label on the device shows which class (A the following measures: Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 142
. To identify this product, refer to the Series number found on the product. For questions regarding this FCC declaration, contact: Compaq Computer Corporation P. O. Box 692000, Mail Stop 510101 Houston, Texas 77269-2000 Or call (281) 514-3333 To identify this product, refer to the parts, series, or - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 143
or modifications made to this device that are not expressly approved by Compaq Computer Corporation may void the user's authority to operate the equipment. Immunity s EN60950 (IEC950) - Product Safety Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 144
Devices The CD-ROM drive contains a laser device. All Compaq systems equipped with a laser device comply with safety standards, specified herein or in the CD-ROM drive installation guide. s Allow only Compaq Authorized Service Technicians to repair the laser equipment. Compliance with CDRH - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 145
for this product. For more information about Real-Time Clock battery replacement or proper disposal, contact your Compaq Authorized Reseller or your Authorized Service Provider. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 146
household waste. In order to forward them to recycling or proper disposal, please use the public collection system or return them to Compaq, your authorized Compaq Partners, or their agents. WARNING: To reduce the risk of personal injury, do not attempt to recharge the battery, disassemble it - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 147
when standing on conductive floors or dissipating floor mats. s Use conductive field service tools. s Use a portable field service kit with a folding static-dissipating work mat. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 148
any of the suggested equipment for proper grounding, have an Authorized Compaq Reseller install the part. NOTE: For more information on static electricity, or assistance with product installation, contact your Authorized Compaq Reseller. For use with Intel Pentium II Xeon processor-based servers - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 149
For more information on power cord set requirements, contact your Authorized Compaq Dealer. General Requirements The requirements listed below are applicable to all outlet on the computer. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 150
C-2 Power Cord Set Requirements Country-Specific Requirements Use the following table to identify the appropriate accredited agency in your country. Table C-1 Power Cord Set Requirements - By Country Country Australia Accredited Agency EANSW 1 Applicable Note Numbers Austria OVE 1 Belgium - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 151
be Type VCT or VCTF, 3-conductor, 1.0 mm2 conductor size. Wall plug must be a two-pole grounding type with a Japanese Industrial Standard C8303 (7A, 125V) configuration. Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers only - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 152
Setup and Installation Finding on Server Documentation CD x Compaq Server Documentation program group x, xi Compaq Servers Troubleshooting Guide Finding on Server Documentation CD x, xii Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 153
Systems Reference Library CD See SRL Compaq Website xviii Configuration and management of server 1-5 diagram optional controller for simplex drive cage, illustrated 7-14 diagram standard for simplex drive cage, illustrated 7-13 SCSI - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 154
Warranty 1-13 Health logs, server 1-5 help Documentation CD xiii http://www.compaq.com/support/serv ers xiv I icon created x, xi Icons See Symbols on configuration utility 5-1 Installing Rack Products CD Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 155
Compaq rack 3-7 Integrated Management Display arrow keys 6-10 buttons 6-10 check mark 6-10 definition 1-4 error events 6-12 features 1-10 installation 6-2 menu structure 6-13 spinning bar 6-10 symbols 6-11 unviewed events 6-10, 6-12 Integrated Management Log 6-12 Integrated Remote Console Guide - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 156
levels 1-6 RAM documentation reader requirements x Rapid Recovery 1-4 Reader Online Guide accessing xiv Release latch using with server rails 3-24 removal IMD blank illustrated 6-2 Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium II Xeon processor-based servers - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 157
server rail, attaching 3-20 Server Setup and Management pack 5-2 Service Information 6-8 Setup and Install Button defined xii Finding on Server starting from System Configuration Utility 2-6, 2-7 SmartStart and Support Software CD 5-1 SMP operating system support 5-4 Spinning bar, IMD 6-10 SRL how - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 158
3-16 for rack model server installation 3-7 Troubleshooting Button defined xii Troubleshooting Guide Finding on Server Documentation CD x, xii U Failure 1-13 web site, Compaq 7-5 Website Ordering documentation xiv Compaq ProLiant 5500 Servers Setup and Installation Guide For use with Intel Pentium - Compaq ProLiant 5500 | Compaq ProLiant 5500 Setup and Installation Guide Pentium - Page 159
Index-8 Windows 3.1 Installing xi Windows 95 Installing xi Windows NT Installing x www.compaq.com xviii For use with Intel Pentium II Xeon processor-based servers only
ProLiant 5500
Setup and Installation Guide
For Intel Pentium II Xeon Processor-based Servers
First Edition (July 1998)
Part Number 328470-001
Compaq Computer Corporation