Dell DX6004S Hardware Owner's Manual - Page 44
I to Ignore OR, Check the Time and Date
View all Dell DX6004S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 44 highlights
Table 1-2. System Messages (continued) Message Causes Corrective Actions Thermal sensor not detected on x. A memory module without a Replace the memory thermal sensor is installed in module. See "System the specified memory slot. Memory" on page 97. Time-of-day clock stopped. Faulty battery or faulty chip. See "Troubleshooting the System Battery" on page 142. Time-of-day not Incorrect Time or Date set - please run settings; faulty system SETUP program. battery. Check the Time and Date settings. See "Using the System Setup Program and UEFI Boot Manager" on page 51. If the problem persists, replace the system battery. See "System Battery" on page 122. Timer chip Faulty system board. counter 2 failed. See "Getting Help" on page 161. TPM configuration operation honored. System will now reset. A TPM configuration command has been entered. The system will reboot and execute the command. Information only. TPM This message displays during Enter I or M to proceed. configuration system restart after a TPM operation is configuration command has pending. Press been entered. User (I) to Ignore OR interaction is required to (M) to Modify to proceed. allow this change and reset the system. WARNING: Modifying could prevent security. TPM failure. A Trusted Platform Module See "Getting Help" on (TPM) function has failed. page 161. 44 About Your System