Table 3-2. System Error Messages (continued) Message Definition Action Stepping of CPU1 is less than sA1 System halted. Wrong microprocessor installed in PROCESSOR1 socket. Replace microprocessor with sA1 stepping or greater. Stepping of CPU2 is less than sA1 System halted. Wrong microprocessor installed in PROCESSOR2 socket. Replace microprocessor with sA1 stepping or greater. Stepping of CPU is less than sA1 System halted. Wrong microprocessor installed in system. Replace microprocessor with correct sA1 stepping or greater. Nonidentical CPUs - System halted. Cache memory sizes of the two Pentium Pro microprocessors do not match. Replace one of microprocessors so that cache size of both microprocessors matches. Invalid CPU speed detected - Check speed jumpers. System halted. The microprocessor speed detected is neither 180 MHz or 200 MHz. Check microprocessor speed jumpers. Power supply paralleling board firmware download failed System backplane firmware download failed Server-management bus cable connection to SCSI backplane board is loose. Check servermanagement bus cable connections to system board (labeled "SMB BACKPLANE") and SCSI backplane (labeled "SMB"). Turn off and then restart system. Embedded server management firmware download failed Embedded server management memory temporarily corrupted. Turn off and then restart the system. Beep Codes and Error Messages 3-5