Dell PowerEdge 4350 Dell PowerEdge 4350 Systems Installation and Troubleshooti - Page 98

Go to step 9.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208

7-16
Dell PowerEdge
4350 Systems Installation and Troubleshooting Guide
Are the appropriate cables firmly attached to their connectors?
Yes.
Go to step 8.
No.
Go to step 7.
7.
Reconnect the cable connectors to the appropriate connectors on the expansion
cards, close the panel doors, reconnect the system to the electrical outlet, and
restart the system.
Is the problem resolved?
Yes.
The cable connections were loose. You have fixed the problem.
No.
Go to step 8.
8.
If applicable, inspect all jumpers and configuration switches on each expansion
card.
For instructions on jumpers and configuration settings, see the expansion card±s
documentation.
Is each expansion card configured correctly?
Yes.
Go to step 10.
No.
Go to step 9.
9.
Reconfigure the card according to the instructions in the card±s documentation.
Is the problem resolved?
Yes.
The memory configuration of the card was incorrect. You have fixed the
problem.
No.
Go to step 10.
10.
Remove all expansion cards.
See ²Removing an Expansion Card³ in Chapter 8 for information on removing
expansion cards.
11.
Close the computer panel doors, reconnect the system to the electrical outlet,
and turn on the system.
12.
Enter the System Setup program, and update the system configuration
information.
See Chapter 4, ²Using the System Setup Program,³ in the system
User±s Guide
for instructions.
13.
Run the RAM test group in the Dell Diagnostics.
See Chapter 5, ²Running the Dell Diagnostics.³