Dell PowerEdge R840 EMC Installation and Service Manual - Page 160

Video specifications, Environmental specifications

Page 160 highlights

Video specifications R840 servers support the integrated Matrox G200eW3 graphics controller with 16 MB of video frame buffer. The following table describes the supported video resolution options. Table 32. Supported video resolution options Resolution Refresh rate (Hz) 1024 x 768 60 1280 x 800 60 1280 x 1024 60 1360 x 768 60 1440 x 900 60 1600 x 900 60 1600 x 1200 60 1680 x 1050 60 1920 x 1080 60 1920 x 1200 60 Color depth (bits) 8, 16, 32 8, 16, 32 8, 16, 32 8, 16, 32 8, 16, 32 8, 16, 32 8, 16, 32 8, 16, 32 8, 16, 32 8, 16, 32 NOTE: 1920 x 1080 and 1920 x 1200 resolutions are supported only in reduced blanking mode. Environmental specifications NOTE: For additional information about environmental certifications, see the Product Environmental Datasheet located with the Manuals & Documents at Dell.com/poweredgemanuals. Table 33. Temperature specifications Temperature Storage Continuous operation (for altitude less than 950 m or 3117 ft) Maximum temperature gradient (operating and storage) Specifications -40-65°C (-40 °F-149°F) 10-35°C (50 °F-95°F) with no direct sunlight on the equipment 20°C/h (36°F/h) Table 34. Relative humidity specifications Relative humidity Storage Operating Specifications 5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be noncondensing at all times. 10% to 80% RH with 29°C (84.2°F) maximum dew point. Table 35. Maximum vibration specifications Maximum vibration Specifications Operating Storage 0.26 Grms at 5 Hz to 350 Hz (all operation orientations) 1.88 Grms at 10 Hz to 500 Hz for 15 minutes (all six sides tested) 160 Technical specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177

Video specifications
R840 servers support the integrated Matrox G200eW3 graphics controller with 16 MB of video frame buffer.
The following table describes the supported video resolution options.
Table 32. Supported video resolution options
Resolution
Refresh rate (Hz)
Color depth (bits)
1024 x 768
60
8, 16, 32
1280 x 800
60
8, 16, 32
1280 x 1024
60
8, 16, 32
1360 x 768
60
8, 16, 32
1440 x 900
60
8, 16, 32
1600 x 900
60
8, 16, 32
1600 x 1200
60
8, 16, 32
1680 x 1050
60
8, 16, 32
1920 x 1080
60
8, 16, 32
1920 x 1200
60
8, 16, 32
NOTE:
1920 x 1080 and 1920 x 1200 resolutions are supported only in reduced blanking mode.
Environmental specifications
NOTE:
For additional information about environmental certifications, see the
Product Environmental Datasheet
located
with the Manuals & Documents at
Dell.com/poweredgemanuals
.
Table 33. Temperature specifications
Temperature
Specifications
Storage
–40–65°C (–40 °F–149°F)
Continuous operation (for altitude less than 950 m
or 3117 ft)
10–35°C (50 °F–95°F) with no direct sunlight on the equipment
Maximum temperature gradient (operating and
storage)
20°C/h (36°F/h)
Table 34. Relative humidity specifications
Relative humidity
Specifications
Storage
5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere must be
noncondensing at all times.
Operating
10% to 80% RH with 29°C (84.2°F) maximum dew point.
Table 35. Maximum vibration specifications
Maximum vibration
Specifications
Operating
0.26 G
rms
at 5 Hz to 350 Hz (all operation orientations)
Storage
1.88 G
rms
at 10 Hz to 500 Hz for 15 minutes (all six sides tested)