Dell PowerEdge R840 EMC Installation and Service Manual - Page 164
Particulate and gaseous contamination specifications
![]() |
View all Dell PowerEdge R840 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 164 highlights
Table 42. Configuration-based ambient temperature restrictions with PCIe (continued) TDP(W) R840 • 8 x 2.5 inch SAS/SATA • 2 x CPU • 6 x PCIe R840 • 8 x 2.5 inch SAS/SATA • 4 x CPU • 6 x PCIe R840 • 24 x 2.5 inch SAS/SATA • 2 x CPU • 6 x PCIe R840 • 24 x 2.5 inch SAS/SATA • 4 x CPU • 6 x PCIe C40E 35 30 C40E 35 30 C40E 35 30 C40E 35 30 45 45 45 45 105 Y Y Y Y YY Y Y Y Y Y Y 100 Y Y Y Y YY Y Y Y Y Y Y 85 Y Y Y Y YY Y Y Y Y Y Y 70 Y Y Y Y YY Y Y Y Y Y Y R840 • 24 x 2.5 inch NVMe • 4 x CPU • 6 x PCIe C40 35 30 E45 N Y Y N Y Y N Y Y N Y Y N=Not Supported Y=Supported NOTE: C40E45 = Continuous operating temperature at 40°C, and Excursion temperature at 45°C. Particulate and gaseous contamination specifications The following table defines the limitations that help avoid any damages to the IT equipment and/or, or both failure from particulates and gaseous contamination. If the levels of particulates or gaseous pollution exceed the specified limitations and result in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer. Table 43. Particulate contamination specifications Particulate contamination Air Filtration Specifications Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit. NOTE: This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. NOTE: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles. NOTE: This condition applies to data center and nondata center environments. Corrosive dust • Air must be free of corrosive dust. • Residual dust present in the air must have a deliquescent point less than 60% relative humidity. NOTE: This condition applies to data center and nondata center environments. Table 44. Gaseous contamination specifications Gaseous contamination Copper Coupon Corrosion Silver Coupon Corrosion Specifications
![](/manual_guide/products/dell-poweredge-r840-emc-installation-service-manual-fc1c869/164.png)