Dell TL2000 User Guide - Page 155

Service Library: Key Path Diagnostics, Important, Drive Test, Ethernet Test, EKM Path Test

Page 155 highlights

a77ug075 This page provides the system administrator with general tests to verify the usability and reliability of the library. The "System Test" will use resident data cartridges to test the load and unload capability of the drives, and ensure that the library mechanics are working satisfactorily. No data will be written to the cartridges and the cartridges will be returned to their normal slot location. The "Slot To Slot" test will move each resident data cartridge from one slot to another, for each test cycle requested. When completing the "Slot To Slot" test, you will need to Inventory your library before placing it back online, since this test scrambles the cartridge slot locations. The user selects the number of test cycles before starting the test from the EXECUTE button. To cancel the test before it completes the cycles, select the STOP button. Note: The Web User Interface System Status screen will indicate progress and completion of the activity. Figure 5-57. Service Library: Perform Diagnostics page The first field can be modified to set the number of cycles. The second field displays the cycles completed. Service Library: Key Path Diagnostics Please refer to http://support.dell.com to determine the availability of this feature. Important: Ensure that library firmware and drive firmware are up to date before running the Key Path Diagnostic. Library firmware level must be greater than 6.xx. See "Verifying/Updating Firmware" on page 4-18. The key path diagnostics test provides the ability to perform diagnostics on the encryption key path. Only drives that are set up for library managed encryption will be tested. Only encryption capable drives in logical libraries that are configured for Library Managed Encryption will be tested. To configure the library for encryption, refer to "Configure Library: Encryption" on page 5-47. The test consists of four parts: v Drive Test: The library performs a drive communication test to confirm communication with the drive. v Ethernet Test: For each EKM IP address, the library performs a ping test and records the results. v EKM Path Test: For each EKM IP address that passed the ping test, the library performs an EKM communication test. v EKM Config Test: This test confirms that a drive is correctly configured in the EKM to service key requests. To run the Key Path Diagnostic, complete the following procedure. 1. Log on to the Web User Interface. Refer to "Login" on page 2-5. Chapter 5. Operations 5-61

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277

This page provides the system administrator with general tests to verify the
usability and reliability of the library. The "System Test" will use resident data
cartridges to test the load and unload capability of the drives, and ensure that the
library mechanics are working satisfactorily. No data will be written to the
cartridges and the cartridges will be returned to their normal slot location. The
"Slot To Slot" test will move each resident data cartridge from one slot to another,
for each test cycle requested. When completing the "Slot To Slot" test, you will
need to Inventory your library before placing it back online, since this test
scrambles the cartridge slot locations.
The user selects the number of test cycles before starting the test from the
EXECUTE button. To cancel the test before it completes the cycles, select the STOP
button.
Note:
The Web User Interface System Status screen will indicate progress and
completion of the activity.
The first field can be modified to set the number of cycles. The second field
displays the cycles completed.
Service Library: Key Path Diagnostics
Please refer to
to determine the availability of this feature.
Important:
Ensure that library firmware and drive firmware are up to date before
running the Key Path Diagnostic. Library firmware level must be
greater than 6.xx. See “Verifying/Updating Firmware” on page 4-18.
The key path diagnostics test provides the ability to perform diagnostics on the
encryption key path. Only drives that are set up for library managed encryption
will be tested. Only encryption capable drives in logical libraries that are
configured for Library Managed Encryption will be tested. To configure the library
for encryption, refer to “Configure Library: Encryption” on page 5-47.
The test consists of four parts:
v
Drive Test:
The library performs a drive communication test to confirm
communication with the drive.
v
Ethernet Test:
For each EKM IP address, the library performs a ping test and
records the results.
v
EKM Path Test:
For each EKM IP address that passed the ping test, the library
performs an EKM communication test.
v
EKM Config Test:
This test confirms that a drive is correctly configured in the
EKM to service key requests.
To run the Key Path Diagnostic, complete the following procedure.
1.
Log on to the Web User Interface. Refer to “Login” on page 2-5.
a77ug075
Figure 5-57. Service Library: Perform Diagnostics page
Chapter 5. Operations
5-61