Epson EPL-8000 User Manual - Page 97
CTS - When CTS Clear To Send is OFF, the signal level is, DSR - When DSR Data Set Ready is OFF
View all Epson EPL-8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
Level 2 Options l DSR - When DSR (Data Set Ready) is OFF, the signal level is permanently set HIGH, allowing the printer to send data to the computer. The factory setting is OFF (signal level HIGH). For most communications purposes, this option should be set to OFF. When DSR is ON, data is sent to the computer only when DSR is HIGH. Menu/submenu Available options ON or OFF l CTS - When CTS (Clear To Send) is OFF, the signal level is permanently set HIGH. The factory setting is OFF (signal level is HIGH). This setting should be set to OFF for most communications purposes. When CTS is ON, data is sent to the computer only when CTS is HIGH. Menu/submenu Available options ON or OFF SelecType 3-29
Level 2 Options
l
DSR - When DSR (Data Set Ready) is OFF, the signal
level is permanently set HIGH, allowing the printer to send
data to the computer. The factory setting is OFF (signal level
HIGH). For most communications purposes, this option should
be set to OFF. When DSR is ON, data is sent to the computer
only when DSR is HIGH.
Menu/submenu
Available options
ON or OFF
l
CTS - When CTS (Clear To Send) is OFF, the signal level is
permanently set HIGH. The factory setting is OFF (signal level
is HIGH). This setting should be set to OFF for most
communications purposes. When CTS is ON, data is sent to
the computer only when CTS is HIGH.
Menu/submenu
Available options
ON or OFF
SelecType
3-29