HP CM3530 Service Manual - Page 479
FUSER ERROR, 1Y Error To continue turn off and then, controller PCA J106.
UPC - 884420196501
View all HP CM3530 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 479 highlights
Table 7-12 Control-panel messages (continued) Control panel message Description 50.8 FUSER ERROR The fuser has experienced a lowtemperature error. 50.9 FUSER ERROR The fuser has experienced a hightemperature error. 51.1Y Error To continue turn off and then There is a beam detect error. on ● 51.10=black ● 51.11=cyan ● 51.12=magenta ● 51.13=yellow 51.2Y Error To continue turn off and then There is a laser error. on ● 51.20=black ● 51.21=cyan ● 51.22=magenta ● 51.23=yellow 52.00 Error To continue turn off and then The laser scanner experienced a startup on error. Recommended action 1. Remove any paper jams from the fuser area. 2. Reinstall the fuser. Check the connector (J50) between the fuser and the product. Replace the cable or fuser if the connector is damaged. 3. If the problem persists, replace the fuser. See Fuser on page 200. 1. Reinstall the fuser. Check the connector (J150) between the fuser and the product. Replace the cable or fuser if the connector is damaged. 2. If the problem persists, replace the fuser. See Fuser on page 200. 1. Turn the product off and then on. 2. Check the flat flexible cable (FFC) connections to the laser scanners. Also check connectors J111 and J110 at the DC controller, and check connectors J503 and J501 at the laser scanners 3. Replace the specific laser scanner. See Laser/scanner assembly (C/Bk) on page 332 or Laser/scanner assembly (Y/M) on page 325. 1. Turn the product off and then on. 2. Check the connectors on the laser scanner. 3. Replace the specific laser scanner. See Laser/scanner assembly (C/Bk) on page 332 or Laser/scanner assembly (Y/M) on page 325. 1. Perform the laser scanner component tests in the Troubleshooting menu. 2. Depending on the test results, perform one of the following steps: ◦ If the cyan or black component tests showed a startup failure, reconnect the connectors of the cyan/black scanner motor (J56 and J58) and the DC controller PCA (J106). ◦ If the yellow or magenta component tests showed a startup failure, reconnect the connectors of the yellow/magenta scanner motor (J55 and J57) and the DC controller PCA (J106). 3. Replace the cyan/black laser scanner unit or the yellow/magenta laser ENWW Control-panel messages 449