HP CM3530 Service Manual - Page 482
Error To continue turn off and then, To continue turn off then
UPC - 884420196501
View all HP CM3530 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 482 highlights
Table 7-12 Control-panel messages (continued) Control panel message Description 57.04 Error To continue turn off and then The low-voltage power-supply fan (FM1) on experienced an error. 57.07 Error To continue turn off and then The delivery area cooling fan (FM3) on experienced an error. Recommended action 1. Reconnect the connector J119 on the DC controller PCA. 2. Immediately after turning on the product, measure the voltage between the connector J119-1 and J119-3 on the DC controller PCA. If the voltage changes from 0 V to approximately 24 V, replace the power-supply fan. 1. Reconnect the connector J27 of the delivery fan, connector J262 on the high voltage power supply D PCA, and connector J114 on the DC controller PCA. 2. Immediately after turning on the product, measure the voltage between the connector J262-4 and J262-6 on the high-voltage power supply D PCA. If the voltage changes from 0 V to approximately 24 V, replace the delivery fan. 59.30 Error To continue turn off and then The fuser motor experienced a startup error. 1. Perform the fuser motor component test on in the Troubleshooting menu. 2. Reconnect the connector J117 on the DC controller PCA. 3. Replace the fuser motor. See Fuser motor on page 345. 59.40 Error To continue turn off and then The fuser motor experienced a rotational on error. 1. Perform the fuser motor component test in the Troubleshooting menu. 2. Reconnect the connector J117 on the DC controller PCA. 3. Replace the fuser motor. See Fuser motor on page 345. 59.5Y ERROR To continue turn off then on A drum motor has experienced a startup error. 1. Perform the drum-motors component test in the DIAGNOSTICS menu. ● Y=0: Black (drum motor 3) (M5) (J121) 2. Reconnect the connectors J120 or J121 ● Y=1: Cyan (drum motor 2) (M4) (J120) on the DC controller PCA. 3. Replace the appropriate drum motor. ● Y=2: Magenta (drum motor 1) (M3) (M4) See Drum motor 1 on page 343 or Drum (J120) motor 2 or drum motor 3 on page 344. ● Y=3: Yellow (drum motor 1) (M3) (J120) 59.6Y ERROR To continue turn off then on A drum motor has experienced a rotational 1. Perform the drum-motors component error. test in the DIAGNOSTICS menu. ● Y=0: Black (drum motor 3) (M5) (J121) 2. Reconnect the connectors J120 or J121 ● Y=1: Cyan (drum motor 2) (M4) (J120) on the DC controller PCA. 3. Replace the appropriate drum motor. See Drum motor 1 on page 343 or Drum motor 2 or drum motor 3 on page 344. 452 Chapter 7 Solve problems ENWW