HP GbE2c HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based
HP GbE2c - Blc Layer 2/3 Fiber SFP Option Manual
UPC - 808736802215
View all HP GbE2c manuals
Add to My Manuals
Save this manual to your list of manuals |
HP GbE2c manual content summary:
- HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 1
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based Interface Reference Guide Part number: 418117-003 Third edition: December 2006 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP the U.S. and other countries. Cisco® is a registered trademark of Cisco Systems, Inc. and/or its affiliates - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 3
...8 Additional references ...8 Features...8 Requirements...8 Switch setup ...8 Configuring IP interfaces ...8 Enabling or disabling BBI access...9 Web browser setup...9 Starting the BBI ...9 Browser-based interface basics Introduction ...12 Toolbar...12 Context buttons...12 Commands...13 Navigation - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 4
CPU Utilization ...71 FDB Statistics ...71 Network Time Protocol Statistics...72 Switch Ports Statistics Summary...73 Port Statistics ...74 Bridging ("dot1") Statistics ...75 Interface ("if") Statistics - Input...75 Interface ("if") Statistics - Output ...76 Ethernet ("dot3") Statistics ...76 GEA IP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 5
Management Processor Configuration 114 Basic system configuration ...114 SNMP controls...116 Switch Management Processor Configuration buttons 117 User Configuration Table ...118 User Access Control Configuration ...118 Switch RADIUS Configuration ...119 Switch TACACS+ Configuration ...121 NTP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 6
General Configuration...190 Virtual Routers Configuration ...190 Virtual Router Configuration ...191 VRRP Interfaces Configuration...193 VRRP Interface Configuration ...194 VRRP General Configuration...195 Domain Name System Configuration...196 Bootstrap Protocol Relay Configuration 197 IP Routing - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 7
Uplink Failure Detection Configuration...207 Failure Detection Pair Configuration 208 Getting started 7 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 8
of access for switch management. For more information about configuring an IP interface for management access, see the "Using the command line interface" section in the "Accessing the switch" chapter of the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Application Guide. Getting started 8 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 9
more information on accessing and configuring the switch through the command line interface, see the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide. Web browser setup Most modern Web browsers work with frames and JavaScript by default, and require no additional set - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 10
in to the switch. If your switch and browser are properly configured, you will be asked to enter a password. Enter the account name and password for the switch. For more password information, see the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide. Getting started 10 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 11
BBI Dashboard page to load. When the proper account name and password combination is entered, the BBI Dashboard page is displayed in the . When loading is complete, a folder icon for the switch displays in the left-hand BBI window. Click this folder and a tree of folders displays. Getting - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 12
toolbar contains buttons and commands used to access and execute switch functions. Context buttons The toolbar is used for setting the context for your actions in the application. There are three context buttons: Table 1 Context buttons Button Description Configure Statistics Dashboard When - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 13
on the switch (with the option of not overlaying the current backup). Removes pending configuration changes between Apply commands. Use this command to restore configuration parameters set since last Apply command. Shows any pending configuration changes. Writes current switch configuration to the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 14
such as settings, status, or statistics. Others allow you to make configuration changes to switch parameters. NOTE: Some items display blank forms, depending on the context. A blank form indicates that no information or actions are available in that context. Browser-based interface basics 14 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 15
the switch's command line interface is present on the dashboard forms. The following provides a basic outline for viewing the dashboard forms. You should first be familiar with configuration as covered in the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide. Steps - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 16
3. View information shown in the forms window. NOTE: Items that load other forms when selected are underlined. 4. Select an underlined item to view details or perform actions. Dashboard 16 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 17
In this example, click a Spanning Tree Group number to view detailed information about the group (shown in form below). Dashboard 17 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 18
Time Last Boot Time Time and date Displays the name of the switch, as entered in Configuration > Switch > General (SNMP). Displays the location of the switch, as entered in Configuration > Switch > General (SNMP). Displays the type of switch. Displays the serial number of the chassis in which the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 19
the numeric identifier for the user Displays the name of the user. Displays the Class of Service level for the user. Indicates whether a valid password is defined for the user. Displays whether the user is enabled or disabled. Displays the login status of the user (online or offline). Dashboard 19 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 20
server. Displays the status of the RADIUS back door for telnet/SSH/ HTTP/HTTPS. Displays the status of the RADIUS back door using secure password for telnet/SSH/ HTTP/HTTPS. Displays the shared secret between the switch and the RADIUS server(s). Displays the secondary shared secret between the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 21
telnet. The telnet command also applies to SSH/SCP connections and the Browser-based Interface (BBI). This command does not apply when secure backdoor (secbd) is enabled. Displays the status of the TACACS+ back door using secure password for telnet/SSH/ HTTP/HTTPS. This command does not apply when - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 22
the GbE2c privilege-level mapping. Switch Image and Configuration Management Dashboard To display the following form, select System > Config/Image Control. The following table describes the Switch Image and Configuration Dashboard controls: Table 7 Switch Image and Configuration Dashboard - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 23
Network Definition Dashboard To display the following form, select System > Mgmt. The following table describes the Management Network Definition Subnet Mask Displays the entry number for each management network. Displays the IP address of the management network. Displays the subnet mask of the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 24
: Shows if Port Fast Forwarding is enabled or disabled. tagging: Shows if this port has VLAN Tagging enabled or disabled. PVID: VLAN ID of any VLAN(s) to which this port is a member. Operational Status Speed/Duplex/Flow Ctl Input Frames/Output Frames Link State Changes/Total Errors Displays the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 25
fields: Table 10 802.1x System information Control System Capability System Status Protocol Version Description Displays the capability of the GbE2c as an 802.1x Authenticator. It cannot be used as an Authentication Server or a Supplicant. Displays the current state (enabled or disabled) of 802 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 26
Ports 802.1x Dashboard To display the following form, select Layer 2 > 802.1x > Switch Ports. The following table describes the Switch Ports 802.1x Dashboard fields: Table 11 Switch Ports 802.1x Dashboard Field Description Port Auth Mode Auth Status Ctrl Dir Displays each port's name. Displays - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 27
Table 11 Switch Ports 802.1x Dashboard Field Authenticator PAE State Backend Auth State Description Displays the • success • fail • timeout • idle Port 802.1x Dashboard Operations To display the following form, go to the Switch Ports 802.1x dashboard. Select a port number. Dashboard 27 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 28
Status Controlled Direction Authenticator PAE State Backend Authentication State Reset Reauthenticate Displays the Access Control authorization mode for the the supplicant (client) attached to the port. This command only applies if the port's 802.1x mode is configured as auto. Dashboard 28 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 29
. For example, 08:00:20:12:34:56 Removes learned FDB entries. Displays the numeric identifier of the FDB entry. Displays the MAC address of the FDB entry. Displays the VLAN number of the FDB entry. Displays the source port of the FDB entry. Displays the trunk number of the FDB entry, if applicable - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 30
, no outbound port is indicated. VLANs Dashboard To display the following form, select Layer 2 > Virtual LANs (click the underlined text, not the folder). This form displays information for all configured VLANs and all member ports that have an active link state. The following table describes the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 31
Layer 2 > Spanning Tree Groups (click the underlined text, not the folder). The following table describes the Switch Spanning Tree Groups Information controls: Table 15 Switch This command does not apply to MSTP. Specifies, in seconds, how often the root bridge transmits a configuration bridge - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 32
configuration bridge protocol data unit before it reconfigures the STP network. If the bridge is not the root bridge, it uses the MaxAge value of the root bridge. This command detailed information. Switch Spanning Tree Group Information To display the following form, go to the Switch Spanning Tree - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 33
is turned on or off for the switch. VLANs Current Root Path Cost Root Port Max bridge. Specifies, in seconds, how often the root bridge transmits a configuration bridge protocol data unit (BPDU). Any bridge that is not the root default after the link speed has been auto negotiated. Dashboard 33 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 34
includes the port priority (hex) and the port number (hex). Switch Trunk Groups Dashboard To display the following form, select Layer 2 > Trunk Groups. When trunk groups are configured, you can view the state of each port in the various trunk groups. NOTE: If Spanning Tree Protocol on any port in - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 35
following form, select Layer 2 > Trunk Hash. The following table describes the Layer 2 (L2) Trunk Hash Dashboard controls: Table 19 Trunk Hash Dashboard controls Control Smac Hash Dmac Hash Sip Hash Dip Hash Description Displays the status of the source MAC hash: enabled or disabled. Displays - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 36
selected to be part of a Link Aggregation Group. Shows the value of the port priority. Displays the aggregator associated with each port. Displays the value that represents the LACP trunk group number. LACP Port Dashboard To display the following form, go to the Switch LACP Dashboard. Select a port - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 37
Fast General Information To display the following form, select Layer 2 > Uplink Fast. The following table describes the underlined text, not the folder). This form displays information for all configured RMON History Groups. The following table describes the RMON History Group Dashboard controls - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 38
Table 22 RMON History Group Dashboard controls Control Description Search Range Search Options RMON History Group ID MIB Object Number of Buckets Requested Granted Buckets Polling Interval Owner To search for a History Group, enter a range of numbers in the From and To fields. To focus the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 39
This form displays information for all configured RMON Alarm Groups. The following table describes the index that is triggered when a rising threshold is crossed. Displays the falling alarm event index that is triggered when a falling threshold is crossed. Displays the alarm type as rising, falling, - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 40
, not the folder). This form displays information for all configured RMON Event Groups. The following table describes the RMON Event time that passed since the last switch reboot, when the most recent event was triggered. This value is cleared when the switch reboots. Displays a text description of - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 41
IP Interface status: enabled (green), disabled (red), or enabled but down (blue). Displays the numeric identifier of the IP Interface. Displays the IP address of the IP Interface. Displays the Subnet Mask of the IP Interface. Displays the IP Broadcast address for this IP Interface. Displays the VLAN - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 42
form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Network Routes (click the IP static route, enter search parameters: • Route Type • Route Tag • Routes for a Destination IP • Routes to a Gateway IP • Route for an IP Interface Fields - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 43
broadcast multicast martian The address belongs to a host or subnet attached to the switch. The address is a static route which has been configured on the GbE2c. The address belongs to one of the switch's IP interfaces. The address was learned by the Routing Information Protocol (RIP). The address - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 44
ARP Cache Information To display the following form, select Layer 3 > ARP (click the underlined text, not the folder). The ARP information includes IP address and MAC address of each entry, address status flags, VLAN, and port for the address, and port referencing information. The following table - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 45
Indirect Unresolved Permanent entry created for switch IP interface Indirect route entry Unresolved ARP entry. The MAC address has not been learned. Default Gateways Dashboard To display the following form, select Layer 3 > Default Gateways (click the underlined text, not the folder). The - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 46
, select Layer 3 > IGMP > IGMP Snooping (click the underlined text, not the folder). IGMP Multicast Groups The following table describes the IGMP Multicast Groups information. Table 32 IGMP Multicast Groups information Field Description Group VLAN Version Ports Expires Displays the IP address - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 47
commands used to display information about IGMP Multicast Routers. Table 33 IGMP Multicast Routers information Field Description VLAN Port Version Expires Max Query Resp. Time Displays the VLAN IGMP Static Multicast Router Configuration To display the following form, select Layer 3 > IGMP > - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 48
This form summarizes general OSPF information. OSPF Areas Dashboard NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > OSPF > OSPF Areas (click the underlined text, not the folder). Select an area number to view statistics - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 49
form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > OSPF > Summary Ranges Enabled or Disabled. Displays the area index associated with the summary range. Indicates whether the summary range is hidden. Displays the base IP address - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 50
form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > OSPF > OSPF Interfaces (click the underlined text, not the folder). The following table describes the OSPF IP Interfaces Dashboard controls. Select an IP Interface ID number to view - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 51
the virtual link, either Enabled or Disabled. Displays the area number associated with the virtual link. Displays the neighbor router ID. Displays the transit delay value, in seconds. RIP General Information NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 52
is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > RIP > RIP Interfaces (click the underlined text, not the folder). The following table describes the RIP Interfaces Dashboard controls: Table 39 RIP Interfaces Dashboard controls Control - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 53
the authentication key for the interface. Displays whether Split Horizon is enabled or disabled. Virtual Router Group Operation NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > VRRP > General. The following table - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 54
Virtual Routers Dashboard NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > VRRP > Virtual Routers (click the underlined text, not the folder). The following table describes the Virtual Routers Dashboard controls: Table - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 55
on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the Virtual Routers Dashboard. Select a virtual router number. The following table describes the Virtual Router Operation controls: Table 42 Virtual Router Operation controls Control Set Virtual Router to Backup - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 56
only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Bootstrap Protocol Relay. This form summarizes BOOTP information. IP Routing Dashboard NOTE: IP Routing is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 57
CoS Dashboard To display the following form, select QoS > 802.1p > Priority - CoS. This form shows the mapping between 802.1p Priority and Class of Service queue assignment. 802.1p CoS Weight Dashboard To display the following form, select QoS > 802.1p > CoS - Weight. This form shows the scheduling - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 58
the following form, select Access Control > Access Control Lists (click the underlined text, not the folder). This form summarizes information for configured Access Control Lists (ACLs). Access Control List Dashboard To display the following form, go to the Access Control Lists form. Select an - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 59
following form, select Access Control > Access Control List Groups (click the underlined text, not the folder). This form summarizes information for configured Access Control List (ACL) Groups. Access Control List Group Dashboard To display the following form, go to the Access Control List Groups - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 60
status of Uplink Failure Detection. Displays whether the Failure Detection Pair is enabled or disabled. Displays the current status of the Link to Monitor (LtM). Displays the current status of the Link to Disable (LtD). Displays the link status and Spanning Tree information for each port in the LtM - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 61
through the switch's command line interface are present on the BBI statistics forms. The following provides a basic outline for viewing statistics. You should first be familiar with configuration as covered in the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide. Steps - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 62
3. View the statistics in the forms window. For example: NOTE: Items that load other forms when selected are underlined. 4. Select an underlined item to view details on a per port basis. For example: NOTE: This page is refreshed every 5 seconds. Viewing statistics 62 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 63
Click IF Stats to display IF portion of TCP/IP statistics IP Stats ICMP Stats UDP Stats TCP Stats SNMP Stats CPU Utilization FDB Stats Click IP Stats to display IP portion of TCP/IP statistics. Click ICMP Stats to display ICMP portion of TCP/IP statistics. Click UDP Stats to display UDP/SNMP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 64
IP Stats, ICMP Stats, or TCP Stats. The following table describes the interface the interface, including framing layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 65
For any interface that does not support protocol multiplexing, this counter will always be zero (0). For packet-oriented interfaces, the switch). This count includes invalid addresses (for example, 0.0.0.0) and addresses of unsupported Classes (for example, Class E). For entities which are not IP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 66
The number of ICMP messages which this entity (the switch) did not send due to problems discovered within ICMP such as a lack of buffer. This value should not include errors discovered outside the ICMP layer such as the inability of IP to route the resultant datagram. In some implementations there - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 67
icmpOutAddrMaskReps Description The number of ICMP Parameter Problem messages sent. The number of ICMP unacknowledged octets. The limit on the total number of TCP connections the entity (the switch) can support. In entities where the maximum number of connections is dynamic, this object should - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 68
total number of segments received in error (for example, bad TCP checksums). The total number of outstanding switch. The total number of UDP datagrams sent from this entity (the switch). The number of received UDP datagrams that could not be delivered for reasons other than the lack of an application - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 69
number of Messages delivered to the SNMP entity from the transport service. The total number of SNMP Messages that were passed from the SNMP protocol entity to the transport service. The total number of SNMP Protocol Data Units (PDUs) that were delivered to - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 70
in the Message. An object to enable or disable the authentication traps generated by this entity (the switch). The total number of ASN.1 for representing such objects as strings of ones and zeros is called the BER (Basic Encoding Rules, defined in X.209). ASN.1 is a flexible notation that allows one - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 71
: Table 51 CPU Statistics Statistic CpuUtil1Second CpuUtil4Seconds CpuUtil64Seconds Description The utilization of MP CPU over 1 second. It shows the percentage. The utilization of MP CPU over 4 seconds. It shows the percentage. The utilization of MP CPU over 64 seconds. It shows the percentage - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 72
in the following table: Table 53 NTP Statistics Statistic Description Request Sent Responses Received Updates Last update time Current system time The total number of NTP requests the switch sent to the primary NTP server to synchronize time. The total number of NTP responses received from the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 73
Ports Statistics Summary To display the following form, select Switch Ports (click the underlined text, not the folder). This form displays traffic statistics on a port-by-port basis. For more information, select a port number to - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 74
Port Statistics To display the following form, go to the Switch Ports Statistics Summary form. Select a Switch Port number. Viewing statistics 74 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 75
Enables or disables the port. Enables or disables RMON for the port. The next several tables contain specific information about bridging, interface (input and output), and Ethernet the interface, including framing characters. The number of packets, delivered by this sub layer to a higher sub layer, - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 76
when the alignmentError status is returned by the MAC service to the Logical Link Control (LLC) (or other MAC user). Received frames for which multiple error conditions obtained are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 77
is incremented when the frameTooLong status is returned by the MAC service to the LLC (or other MAC user). Received frames for which multiple error conditions obtained are, according to the conventions of IEEE 802.3 Layer Management, counted exclusively according to the error status presented to the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 78
field was not a valid address to be received at this entity (the switch). The number of input IP datagrams for which no problems were encountered to prevent their continued processing, but which were discarded (for example, for lack of buffer space). Note that this counter does not include any - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 79
Ports 802.1x Statistics form. Select a port number. The following table describes 802.1x port statistics: Table 61 Switch Port 802.1x Statistics Statistic Description Authenticator Diagnostics authEntersConnecting Total number of times that the state machine transitions to the CONNECTING - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 80
Table 61 Switch Port 802.1x Statistics Statistic Description authSuccessesWhile Authenticating Total number of times that the state machine transitions from AUTHENTICATING to AUTHENTICATED, as a result of the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 81
Forwarding Database. Highest number of entries recorded at any given time in the Forwarding Database. LACP Statistics To display the following form, select Layer 2 > LACP. Enter a port number to show LACP Statistics for the port. The following table describes LACP statistics: Viewing statistics 81 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 82
was not a valid address to be received at this entity (the switch). This count includes invalid addresses (for example, 0.0.0.0) and addresses of unsupported Classes (for example, Class E). For entities which are not IP Gateways and therefore do not forward datagrams, this counter includes datagrams - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 83
TTL) field of the IP header of datagrams originated at this entity (the switch), whenever a TTL value is not supplied by the transport layer protocol. IP Routing Management Statistics (part one) NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 84
of input datagrams received from interfaces, including those received in error. The total number of input datagrams successfully delivered to IP user-protocols (including ICMP). The number of input datagrams for which this entity (the switch) was not their final IP destination, as a result of which - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 85
The number of times an interface has transitioned from either down to up or from up to down. IP Routing Management Statistics (part 2) NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Network Routes (click the underlined - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 86
GbE2c. This count includes invalid addresses (for example, 0.0.0.0) and addresses of unsupported classes (for example, Class E). For entities which are not IP IP datagrams that have been discarded because they needed to be fragmented at this entity (the switch) but could not be, for example supported - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 87
IP Routing Management Statistics (part 3) NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Network Routes (click the underlined text, not the folder). The following table describes the Internet Control Messaging Protocol - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 88
GbE2c did not send due to problems discovered within ICMP such as a lack of buffer. This value should not include errors discovered outside the ICMP layer such as the inability of IP on the total number of TCP connections the GbE2c can support. In entities where the maximum number of connections - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 89
The total number of segments received in error (for example, bad TCP checksums). The total number of outstanding the reset (RST) flag. The following table describes the User Datagram there was no application at the destination port. ARP Statistics To display the following form, select Layer 3 > ARP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 90
Snooping Statistics Summary To display the following form, select Layer 3 > IGMP > IGMP Snooping (click the underlined text, not the folder). The following table describes IGMP VLAN Snooping statistics: Table 75 IGMP VLAN Snooping Statistics Summary Statistic Description Clear IGMP Statistics - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 91
rxIgmpGrpSpecificQueries rxIgmpLeaves rxIgmpReports txIgmpReports txIgmpGrpSpecificQueries txIgmpLeaves Select Clear and click Submit to clear IGMP statistics for this VLAN. Total number of valid IGMP packets received Total number of General Membership Query packets received Total number - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 92
OSPF General Statistics NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > OSPF > General. Viewing statistics 92 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 93
State Request packets received on all OSPF areas and interfaces. The sum total of all Link State Acknowledgement packets received on all OSPF areas and interfaces. The sum total of all Link State Update packets received on all OSPF areas and interfaces. The sum total of all OSPF packets transmitted - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 94
n1way rst_ad down hello down loop unloop wait timer backup nbr change Description The sum total number of Database interface across all OSPF areas. OSPF Areas Statistics NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 95
OSPF Area Statistics NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the OSPF Areas Statistics form. Select an area number. Viewing statistics 95 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 96
State Request packets received on all OSPF areas and interfaces. The sum total of all Link State Acknowledgement packets received on all OSPF areas and interfaces. The sum total of all Link State Update packets received on all OSPF areas and interfaces. The sum total of all OSPF packets transmitted - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 97
hello down loop unloop wait timer backup nbr change Description The sum total all OSPF areas and interfaces. The sum total number of link state updates received for all interfaces and areas. The sum total number of times the Neighbor adjacency has been reset across all OPSF areas and interfaces - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 98
on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > OSPF > OSPF Interfaces (click the underlined text, not the folder). The following table describes the OSPF IP Interfaces Statistics controls: Table 79 OSPF IP Interface statistics Control Description - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 99
OSPF IP Interface Statistics NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the OSPF IP Interfaces Statistics form. Select an interface ID number. Viewing statistics 99 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 100
State Request packets received on all OSPF areas and interfaces. The sum total of all Link State Acknowledgement packets received on all OSPF areas and interfaces. The sum total of all Link State Update packets received on all OSPF areas and interfaces. The sum total of all OSPF packets transmitted - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 101
during adjacency establishment for all OSPF areas and interfaces. The sum total number of link state updates received for all out-of-date portions across all OSPF interfaces and areas. The sum total number of times the Neighbor adjacency has been reset across all OPSF areas and interfaces. The total - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 102
GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > RIP > General. This form provides basic Routing Information Protocol (RIP) statistics. Virtual Router Redundancy Protocol Statistics NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 103
. The total number of VRRP advertisements that had a bad interval. Domain Name System Statistics To display the following form, select Layer 3 > Domain Name System. The following table describes DNS statistics: Table 82 DNS Statistics Statistic DNS In Requests Bad DNS Requests DNS Out Requests - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 104
select Layer 3 > General. The following table describes IP Routing Management statistic controls: Table 83 IP Interface Management Statistics Controls Statistic Description Clear IP statistics IP Interface Number (1-256) IP Interface Statistics Clears all IP statistics. Selects an interface to - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 105
of input datagrams received from interfaces, including those received in error. The total number of input datagrams successfully delivered to IP user-protocols (including ICMP). The number of input datagrams for which this entity (the switch) was not their final IP destination, as a result of which - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 106
Management Statistics Statistic ifStateChanges Description Total number of interface state changes. IP Routing Management Statistics (part two) To display the following form, select Layer 3 > General. The following table describes Address Resolution Protocol statistics Table 85 ARP Statistics - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 107
The number of ICMP messages which this entity (the switch) did not send due to problems discovered within ICMP such as a lack of buffer. This value should not include errors discovered outside the ICMP layer such as the inability of IP to route the resultant datagram. In some implementations there - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 108
number of TCP connections the entity (the switch) can support. In entities where the maximum number of total number of segments received in error (for example, bad TCP checksums). The total number of RST flag. Switch IP address of TCP connections. TCP port used by the remote device. IP address of TCP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 109
The total number of UDP datagrams delivered to the switch. The total number of UDP datagrams sent from this entity (the switch). The number of received UDP datagrams that could not be delivered for reasons other than the lack of an application at the destination port. The total number of received - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 110
underlined text, not the folder). The following table describes commands for Uplink Failure Detection (UFD) statistics: Table 89 Uplink Detection Statistics Control Clear UFD Statistics Number of times LtM link failure Number of times LtM link in Blocking State Number of times LtD got auto - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 111
the switch's command-line interface are present on the BBI configuration forms. The following provides a basic outline for switch configuration. You should first be familiar with configuration as covered in the HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Command Reference Guide. IMPORTANT - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 112
next time the switch is rebooted, unless the Save command is selected. When you click Save, you have two save options: Save and Save n. With Save, your new configuration changes are placed in the active configuration block. The previous configuration is copied into the backup configuration block. If - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 113
, if you enter a value that is out of range (VLAN = 8097), a log error is generated. • Apply: When you click Apply to make pending changes active, the switch checks the validity of pending configuration changes. For example, an invalid MIB OID can pass the format check during Submit, if the format - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 114
Switch Management Processor Configuration Basic system configuration To display the following form, select System > General. Configuring the switch 114 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 115
necessary, disabling console ensures the switch is not affected by syslog messages. It is enabled by default. Enable/Disable Host Name Enables or disables displaying of the host name (system administrator's name) in the Command Line Interface (CLI). Syslog Host IP Address Sets the IP address of - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 116
SNMP controls To display the following form, select System > General. Configuring the switch 116 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 117
SNMP state machine. Enables or disables the use of the system authentication trap facility. The default setting is disabled. Switch Management Processor Configuration buttons The following table describes the Switch Management Processor Configuration buttons: Table 92 Switch Management Processor - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 118
, select System > User Table. This form summarizes the users configured on the switch. Click Add User to define a new user. Click Change User/Oper/Admin password to configure new passwords for the switch. To remove an end-user from switch, select the user ID and click Eject user. User Access Control - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 119
the Class-of-Service to define the user's authority level. Defines the user name of maximum eight characters. Sets the user password of up to 128 characters maximum. Confirms the user password. Enables or disables the user. Switch RADIUS Configuration To display the following form, select System - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 120
) between the switch and the Radius server(s). IMPORTANT: If RADIUS is enabled, you must login using RADIUS authentication when connecting via the console or Telnet/SSH/HTTP/HTTPS. Backdoor for console is always enabled, so you can connect using noradius and the administrator password even if the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 121
Switch TACACS+ Configuration To display the following form, select System > Tacacs+. TACACS+ (Terminal Access Controller Access Control System) is an authentication protocol that allows a remote access server to forward a user's logon password to an authentication server to determine whether access - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 122
Select the corresponding GbE2c user level. IMPORTANT: If TACACS+ is enabled, you must login using TACACS+ authentication when connecting via the console or Telnet/SSH/HTTP/HTTPS. Backdoor for console is always enabled, so you can connect using notacacs and the administrator password even if the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 123
savings time in the system clock. When enabled, the switch will add an extra hour to the system clock so that it is consistent with the local clock. By default, this option is disabled. Enable/Disable NTP Service Enables or disables the NTP synchronization service. Configuring the switch 123 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 124
Configuration controls Control Description Enable/Disable Syslog and Trap of Console Enable/Disable Syslog and Trap of System Enable/Disable Syslog and Trap of Management Enable/Disable Syslog and Trap of CLI Enable/Disable Syslog and Trap of STP Enable/Disable Syslog and Trap of VLAN Enable - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 125
syslog messages and traps of 802.1x-related events. Enables or disables syslog messages of Uplink Failure Detection (UFD) events. Enables or disables syslog messages of configuration events. Enables or disables event traps of Uplink Failure Detection (UFD) events. Configuring the switch 125 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 126
Switch Image and Configuration Management To display the following form, select System > Config/Image Control. Configuring the switch 126 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 127
running (active or backup). Selects the Configuration Block file (active or backup) that will run after the next reboot. Selects the type of command-line interface (CLI) used after the next reboot. Enter the host name or IP address of the TFPT server from which you will download software. Selects - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 128
operating system, the specified Put Config file must exist prior to executing the Put Config command and must be writable (set with proper permission, and not locked by any application). The contents of the specified file will be replaced with the current configuration data. Configuring the switch - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 129
which switch access is allowed through Telnet, SNMP, or the Browser-based Interface (BBI). A range of IP addresses is produced when used with a network mask address. Specify an IP address in dotted-decimal notation. Specify a mask address in dotted-decimal notation. Configuring the switch 129 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 130
Switch Ports Configuration To display the following form, select System > Switch Ports (click the underlined text, not the folder). This form summarizes the configuration of each port. Select a switch port number to go to its configuration form. Configuring the switch 130 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 131
ports. The following table describes the Switch Port Configuration controls: Table 101 Switch Port Configuration controls Control Description Switch Port State RMON Instrumentation Media Setting VLAN Tagging Enables or disables the port. Enables or disables Remote Monitoring for the port. RMON - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 132
Table 101 Switch Port Configuration controls Control PVID Tagging Port STP Default Port VLAN ID (1-4095) Flow Control Autonegotiation Speed Duplex mode Enable/Disable sending Link UP/Down Trap Port Name Multicast Threshold Multicast Threshold Rate (0-262143) Broadcast Threshold Broadcast Threshold - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 133
Switch Port ACL Configuration To display the following form, go to the Switch Ports Configuration form. Select a Switch Port number. This form allows you to configure Access Control List settings for individual switch ports. Configuring the switch 133 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 134
Port-Based Port Mirroring (click the underlined text, not the folder). This form is used to configure, enable, and disable the Monitoring Port. When enabled, network packets being sent and/or received on a target port are duplicated and sent to a monitor port. By attaching a network analyzer to the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 135
port and the mirrored direction is ingress or both (ingress and egress), the frame is sent to the mirrored port. • If the destination port of the frame matches the mirrored port and the mirrored direction is egress or both, the frame is sent to the monitoring port. Configuring the switch 135 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 136
Control System Status Description Enables or disables 802.1x Port-Based Network Access Control. 802.1x Switch Ports Configuration To display the following form, select Layer 2 > 802.1x > Switch Ports. Select a port number to view the Switch Port 802.1x Configuration form. Configuring the switch - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 137
(default is 3 seconds). Sets the re-authentication status to on or off. The default value is off. Sets the time, in seconds, the authenticator waits before re-authenticating a supplicant (client) when periodic re-authentication is enabled. The default value is 3600 seconds. Configuring the switch - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 138
Table 106 Port 802.1x Configuration controls Control Overwrite Configuration with Description Overwrites the port configuration settings with the global or default 802.1x settings. FDB Configuration To display the following form, select Layer 2 > FDB (click the underlined text, not the folder). - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 139
. Configures the MAC address of the static FDB entry. Configures the VLAN for the static FDB entry. Configures the port for the static FDB entry. VLANs Configuration To display the following form, select Layer 2 > Virtual LANs (click the underlined text, not the folder). Configuring the switch 139 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 140
Add VLAN. The commands on this form configure VLAN attributes, change the status of the VLAN, delete the VLAN, and change the port membership of the VLAN. By default, the VLAN menu option is disabled except VLAN 1, which is enabled all the time. The GbE2c supports a maximum of 1,000 VLANs. VLAN - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 141
more than one VLAN unless the port has VLAN tagging turned on. Switch Spanning Tree Groups Configuration To display the following form, select Layer 2 > Spanning Tree Groups (click the underlined text, not the folder). This form summarizes Spanning Tree Group parameters. The GbE2c supports the IEEE - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 142
Search to display Spanning Tree Groups that fit the range and meet the criteria entered. Switch Spanning Tree Group Configuration To display the following form, go to the Switch Spanning Tree Groups Configuration form. Select a Spanning Tree Group number, or open the Spanning Tree Groups folder and - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 143
state to the forwarding state. The range is 4 to 30 seconds, and the default is 15 seconds. This command does not apply to MSTP. See the "Common Internal Spanning Tree Bridge Configuration" section for more information. VLANs Available Lists the VLANs that can be added to the Spanning Tree Group - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 144
connected to a bridge, and can begin forwarding traffic as soon as the link is up. Configure server ports as edge ports (enabled). This command only applies when RSTP is turned on. Enables or disables Port Fast Forwarding on the port. Enables or disables STP on the port. Configuring the switch 144 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 145
MSTP/RSTP General Configuration To display the following form, select Layer 2 > MSTP/RSTP > General. The switch supports the IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) and IEEE 802.1s Multiple Spanning Tree Protocol (MSTP). MSTP allows you to map many VLANs to a small number of spanning tree - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 146
following configurations are supported: 1 HP PVST+ (default Spanning Tree setting) is interoperable with Cisco PVST+. 2 HP MSTP/RSTP (with mode set to 'mstp') is interoperable with Cisco MST/RSTP. Common Internal Spanning Tree Bridge Configuration To display the following form, select Layer 2 > MSTP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 147
state to the forwarding state. The range is 4 to 30 seconds, and the default is 15 seconds. This command does not apply to RSTP. See the "Switch Spanning Tree Group Configuration" section for more information. Lists the VLANs that can be added to the Common Internal Spanning Tree (CIST). Lists the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 148
edge port. An edge port is not connected to a bridge, and can begin forwarding traffic as soon as the link is up. Configure server ports as edge ports (enabled). This command is disabled by default. Turns MSTP on or off for this port. Configures how often "keep alive" BPDU messages are transmitted - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 149
Layer 2 > Trunk Groups. This form provides a summary of the state of all trunk groups. Switch Trunk Group Configuration To display the following form, go to the Trunk Groups Configuration form. Select a Trunk Group number. This form enables you to configure a selected switch trunk group. Configuring - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 150
controls: Table 118 Layer 2 Trunk Hash Configuration controls Control Description Smac Dmac Sip Dip Enable or disable trunk hashing on the source MAC. Enable or disable trunk hashing on the destination MAC. Enable or disable trunk hashing on the source IP. Enable or disable trunk hashing on the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 151
) or long (90 seconds). The default value is long. Note: HP recommends that you use a timeout value of long, to reduce LACPDU processing. If your switch's CPU utilization rate remains at 100% for periods of 90 seconds or more, consider using static trunks instead of LACP. Configuring the switch 151 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 152
Switch LACP Configuration form. Select a port number. The following table describes the LACP Port Configuration controls: Table 120 LACP Port Configuration controls Control Port Admin Key Port Priority Port LACP Mode Description Set the admin to manually configure a static trunk. The default - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 153
Tree convergence to an upstream switch during failover. Note: When enabled, this feature increases bridge priorities to 65500 for all STGs and path cost by 3000 for all external STP ports. Configures the station update rate. The default value is 40. RMON History Configuration Table To display the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 154
MIB Object Identifier. The interface OID can have a maximum of 127 characters. Number of Buckets Requested (1-65535) Configures the number of requested buckets, which is the number of data slots into which data is to be saved. The range is from 1 to 65535. The default is 30. NOTE: The maximum - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 155
text, not the folder). The following table describes the Alarm Groups Configuration controls: Table 124 RMON Alarm Configuration controls Control Search Range Search Options Description To search for a RMON Alarm that fit the range and meet the criteria entered. Configuring the switch 155 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 156
the falling alarm event index that is triggered when a falling threshold is crossed. The range is from 0 to 65535. The default value is 0. Configures the alarm type as rising, falling, or either (rising or falling). Configures the method of sampling the selected variable and calculating the value to - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 157
entity that uses this alarm index. The owner can have a maximum of 127 characters. RMON Event Configuration Table To display the following form, select RMON > Event (click the underlined text, not the display Events that fit the range and meet the criteria entered. Configuring the switch 157 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 158
provided for this event. For log events, an entry is made in the log table and sent to the configured syslog host. For trap events, an SNMP trap is sent to the management station (/cfg/snmp/trap). Enter uses this Event index. The owner can have a maximum of 127 characters. Configuring the switch 158 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 159
IP Interfaces Configuration To display the following form, select Layer 3 > IP Interfaces (click the underlined text, not the folder). This form summarizes IP Interface parameters. The following table describes IP Interfaces Configuration controls: Table 128 IP Interfaces Configuration controls - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 160
the IP Interface Configuration controls: Table 129 IP Interface Configuration controls Control Description IP Interface Identifier (1-256) IP Address Enabled? Subnet Mask VLAN Membership ID (1-4095) Selects an IP interface to configure. Configures the IP address of the switch interface using - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 161
on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Network Routes (click the underlined text, not the folder). This form summarizes static route parameters. The following table describes IP Static Routes Configuration controls: Table 130 IP Static Routes - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 162
on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the IP Static Routes Configuration form. Select IP address of the gateway associated with this route. Assigns an interface number to this route. Static ARP Configuration To display the following form, select Layer - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 163
ARP Table Index (1-128) IP MAC VLAN Port Configures the table index number for the static ARP entry. Configures the IP address of the host. Configures the MAC address of the host. Configures the VLAN ID for the host. Configures the port to which the host connects. Configuring the switch 163 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 164
available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Network Filters (click the underlined text, not the folder). This form summarizes network filter parameters. The following table describes Network Filters Configuration controls: Table 133 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 165
on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the Network Filters Configuration form. IP address for this filter. The default address is 0.0.0.0 Enables or disables the Network Filter configuration. Sets the IP subnet mask that is used to define the range of IP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 166
only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Route Maps (click the underlined text, not the folder). The following table describes Route Maps Configuration controls: Table 135 Route Maps Configuration controls Control Search Operation - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 167
is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the Route Maps Configuration form. Select a route map ID number, or open the Route Maps folder and click Add Route Map. The following table describes the Route Map Configuration controls: Table 136 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 168
136 Route Map Configuration controls Control Enabled? Description Enables or disables the route map. Route Map Access List Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the Route Map Configuration form. Click Add - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 169
Route Map Access Path Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the Route Map Configuration form. Click Add Access Filter. The following table describes the Access Path Configuration controls: Table 138 Access - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 170
following form, select IP Menu > Default Gateways (click the underlined text, not the folder). This form summarizes default gateway parameters. The following table describes the Default Gateways Configuration controls: Table 139 Default Gateways Configuration controls Control Description Search - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 171
before Out of Service (1-120) Description Selects a default Gateway to configure. Configures the IP address of the default IP gateway using dotted decimal notation. Enables or disables the gateway for use. Enables or disables Address Resolution Protocol (ARP) health checks. This command is disabled - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 172
IGMP Snooping Configuration To display the following form, select Layer 3 > IGMP > IGMP Snooping (click the underlined text, not the folder). Internet Group Management Protocol (IGMP) is used by IP Multicast routers to learn about the existence of host group members on their directly attached subnet - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 173
Source IP for GSQ proxy Configures the source IP address used as a proxy for IGMP Group Specific Queries. Remove all VLANs from IGMP Snooping Removes all VLANs from the list of Snooping VLANs. Configured VLANs Lists the VLANs that can be assigned for IGMP Snooping. Snooping VLANs Enables or - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 174
this filter. Configures the end of the range of IP multicast addresses for this filter. Allows or denies multicast traffic for the IP multicast address range specified. IGMP Filtering Port Configuration To display the following form, select Layer 3 > IGMP > Switch Ports. Configuring the switch 174 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 175
Configuration form. Select a Switch Port number. The following table describes IGMP Filtering - Port Configuration controls: Table 143 IGMP Filtering - Port Configuration controls Control Description Enable Static Multicast Router Configuration To display the following form, select Layer 3 > - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 176
Vlan ID IGMP Version? Selects a port on which the static multicast router is connected. Note: Port number must be an external port (17-18, 20-24). Selects a VLAN on which the static multicast router is connected. Configures the IGMP version (1 or 2) of the multicast router. Configuring the switch - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 177
on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > OSPF Routing Protocol > General. The following table describes the OSPF General Configuration controls: Table 145 OSPF General Configuration controls Control Descriptions Globally Enable OSPF? External - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 178
a numeric identifier for the MD5 authentication key. Assigns a string to the MD5 authentication key. OSPF Areas Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > OSPF Routing Protocol > OSPF Areas (click the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 179
is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the OSPF Areas Configuration form. Select an area number, or open the OSPF Areas folder and click Add OSPF Area. The following table describes the OSPF Area Configuration controls: Table 147 OSPF - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 180
a summary of the state of OSPF summary ranges. OSPF Summary Range Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the OSPF Summary Ranges Configuration form. Select a summary range number, or open the OSPF Summary - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 181
Subnet Mask Descriptions Defines the IP address mask for the range. OSPF Interfaces Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > OSPF Routing Protocol > OSPF Interfaces (click the underlined text, not - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 182
on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the OSPF Interfaces Configuration form. Select an interface number, or open the OSPF Interfaces folder and click Add OSPF Interface. The following table describes the OSPF Interface Configuration controls: Table - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 183
a summary of the state of OSPF virtual links. OSPF Virtual Link Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the OSPF Virtual Links Configuration form. Select a virtual link number, or open the OSPF Virtual - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 184
is none. Sets MD5 key ID for each virtual link. Default is 0 (none). OSPF Hosts Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > OSPF Routing Protocol > OSPF Hosts (click the underlined text, not the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 185
OSPF hosts that fit the range and meet the criteria entered. OSPF Host Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the OSPF Hosts Configuration form. Select a host number, or open the OSPF Hosts folder and click - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 186
available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > OSPF Routing Protocol > OSPF Route Redistribution (click the underlined text, not the folder). The following table describes the OSPF Route Redistribution Configuration controls: Table 154 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 187
RIP Interfaces Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Routing Information Protocol > Routing Information Protocol (click the underlined text, not the folder). RIP is used for configuring Routing - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 188
only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the RIP Interfaces Configuration form. Select a RIP interface number, or open the RIP Interfaces folder and click Add RIP Interface. The following table describes the RIP Interface Configuration controls: Table - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 189
distance to the destination. The default value is 1. Configures the authentication type. The default is none. Configures the authentication key password. RIP Route Redistribution Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 190
on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Routing Information Protocol > General. The following table describes the RIP Interface Configuration controls: Table 158 RIP General Configuration controls Control Descriptions Globally Enable RIP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 191
that fit the range and meet the criteria entered. Virtual Router Configuration NOTE: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the Virtual Routers Configuration form. Select a Virtual Router number or open the Virtual Routers - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 192
160 Virtual Router Configuration controls Control Descriptions Virtual Router Identifier (1-255) IP Address IP Interface (1-255) Enabled? Priority (1-254) Advertisement Interval (1-255) Owner Preemption? Track master virtual routers? Track other IP interfaces? Track VLAN switch ports? Defines - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 193
form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Virtual Router Redundancy Protocol > VRRP Interfaces (click the underline text, not the folder). The following table describes VRRP Interfaces Configuration controls: Table 161 VRRP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 194
: This form is available only on the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, go to the Virtual Routers Configuration form. Select a VRRP interface number or open the VRRP Interfaces folder and click Add Virtual router Interface. The following table describes the VRRP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 195
GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Virtual Router Redundancy Protocol > General. The following table describes the VRRP General Configuration controls: Table 163 VRRP General Configuration controls Control Descriptions VRRP Processing Enabled - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 196
Table 163 VRRP General Configuration controls Control Owner Preemption? Track other IP interface? Track VLAN switch ports? Descriptions Enables or disables master preemption. When enabled, if the virtual router group is in backup mode but has a higher priority than the current master, this virtual - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 197
the GbE2c Layer 2/3 Ethernet Blade Switch. To display the following form, select Layer 3 > Bootstrap Protocol Relay. The following table describes the Bootstrap Protocol Relay configuration controls: Table 165 Bootstrap Protocol Relay Configuration controls Control Description BOOTP Server IP - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 198
* indicates fields that are available only on the GbE2c Layer 2/3 Ethernet Blade Switch. QoS Priority CoS Configuration To display the following form, select QoS > 802.1p > Priority - CoS. This form summarizes the QoS Priority - Class of Service parameters. Select a priority value to view the CoSQ - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 199
Configuration form, and select a CoS value. The following table describes the CoSQ configuration controls: Table 168 CoSQ Configuration controls Control CoSq Weight (0-15) Description Configures the scheduling weight of the selected Class of Service queue (CoSq). Configuring the switch 199 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 200
ACL Configuration To display the following form, select Access Control > Access Control Lists (click the underlined text, not the folder). Configuring the switch 200 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 201
Lists. The following table describes the ACL Configuration controls: Table 169 ACL Configuration controls Control Description Search Range Search Options ID • Switch Egress Port • Source MAC address • Destination MAC address • VLAN ID • Protocol type • Source IP address • Destination IP address • - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 202
Destination MAC Address Description Assigns a numeric identifier to the ACL. Configures a filter action for packets that match the ACL definitions. You can choose to permit (pass) or deny (drop) packets, or set the Class of Service queue that handles the packets. Defines the Ethernet format for the - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 203
Table 170 Access Control List Configuration controls Control Ethernet Type VLAN ID (1-4095) 802.1p Priority Type of Service (0-255) Protocol (0-255) Source IP Address Destination IP Address TCP/UDP Src Port (1-65535) TCP/UDP Dst Port (1-65535) TCP Flags Statistics Egress Port Description Defines - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 204
rate must be a multiple of 64. Configures the maximum burst size, in Kilobits. Enter one of the following values for mbsize: 32, 64, 128, 256, 512, 1024, 2048, 4096 Configures the ACL Meter to either drop or pass out-of-profile traffic. Enables or disables the ACL meter. Configuring the switch 204 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 205
Defines the method used to update 802.1p priority updates, as follows: • User defined - Sets the 802.1p priority for In-Profile packets based on the configured value. • Use TOS precedence - Maps the TOS (Type of Service) priority to 802.1p priority for In-Profile packets. • Disabled - Disables 802 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 206
, enter a range of ACL Group numbers in the From and To fields. Click Search to display ACL Groups that fit the range. Access Control Group Configuration To display the following form, go to the ACL Groups Configuration Table form, and select an ACL Group number. Configuring the switch 206 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 207
Detection (UFD) supports network fault tolerance in network adapter teams. Use this menu to configure a Failure Detection Pair of one Links to Monitor (LtM) group and one Links to Disable (LtD) group. When UFD is enabled and a Failover Pair is configured, the switch automatically disables ports - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 208
Failure Detection Pair Configuration To display the following form, select Uplink Failure Detection (click the underlined text, not the folder). On the UFD Configuration form, select FDP. Configuring the switch 208 - HP GbE2c | HP GbE2c Ethernet Blade Switch for c-Class BladeSystem Browser-based - Page 209
Configuration controls Control Description Enable/Disable FDP LtM Ports Available LtM Ports Selected LtD Ports Available LtD Ports Selected LtM Trunks Available LtM Trunks Selected LtD Trunks Available LtD Trunks Selected Enables that can be added to the Link to Disable (LtD). Only downlink
HP GbE2c Ethernet Blade Switch for c-Class BladeSystem
Browser-based Interface Reference Guide
Part number: 418117-003
Third edition: December 2006