HP Integrity rx2620 Installation (Smart Setup) Guide, Windows Server 2003, v5. - Page 72

Adding a PCI card, Hardware interface for all HP Integrity servers except Superdome

Page 72 highlights

NOTE: You cannot perform a hot-plug addition for some cards unless they replace the same type card in the slot. You cannot hot-add them in a new installation. Although no damage to the server occurs if you attempt a hot-plug addition with these cards, they will not function until the next reboot. The following table lists the PCI cards that do not support hot-plug addition. Table 4-1 PCI cards that do not support hot-plug addition Hot-Plug Operation Supported PCI CARD SA6402 SA6404 SA5300 USB & VGA Graphics Combo Cards I and II (A6869A and A6869B) hot-plug addition Yes Yes Yes No No (replace) hot-plug addition (new) No No No No No In addition, rx3600 and rx6600 PCI Express-based Integrity servers have the following limitations in hot-plug functionality: • Hot-plug operations on PCI Express slots 3 and 4 are currently disabled. • Regarding hot-plug operations on PCI-X slots 7, 8, 9, and 10: Doorbell functionality can be intermittent. You must press the attention button until the power indicator LED is either solidly on or off. Adding a PCI card This section describes how to add a PCI card (called a hot-plug addition) on HP Integrity servers running Windows Server 2003. Before performing hot-plug additions or deletions to HP Integrity servers, ensure the following: • On HP Integrity rx7620, rx7640, rx8620, rx8640, and Superdome servers, you must install the latest version of the OpRegion driver. This driver is not required on the rx4640 server. • HP Integrity rx4640 server slots 2 to 3 and 4 to 5 are shared PCI hot-plug slots. For optimal hot-plug operation, use the same type of PCI cards in these shared slots. For example, if a PCI-X 133 MHz card is in slot 4, the insertion of a PCI 66 MHz card in slot 5 will fail because the slot has been set at 133 MHz. However, if a PCI-X 66 MHz card is in slot 3, the insertion of a PCI-X 133 MHz in slot 2 will be successful, although both cards will run at 66 MHz. The rx7620 and rx8620 do not have shared slots and are therefore not subject to these restrictions. • Ensure that the server has the latest version of the system firmware installed. Hardware interface for all HP Integrity servers except Superdome To perform hot-plug additions using the server hardware interface for all HP Integrity servers except Superdome, complete the following steps: 1. Locate an empty slot. 2. If the power light is on for the slot, press the attention button to start the power-off sequence. (If the power light is not on, you do not need to press the attention button.) The power LED will blink for 5 seconds. While the power LED is flashing, you can cancel the power-off sequence by pressing the attention button again. 72 Performing hot-plug operations

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

NOTE:
You cannot perform a hot-plug addition for some cards unless they replace the same
type card in the slot. You cannot hot-add them in a new installation. Although no damage to the
server occurs if you attempt a hot-plug addition with these cards, they will not function until
the next reboot. The following table lists the PCI cards that do not support hot-plug addition.
Table 4-1 PCI cards that do not support hot-plug addition
PCI CARD
USB & VGA Graphics Combo Cards I
and II
(A6869A and A6869B)
SA5300
SA6404
SA6402
Hot-Plug Operation
Supported
No
No
Yes
Yes
Yes
hot-plug addition
(replace)
No
No
No
No
No
hot-plug addition (new)
In addition, rx3600 and rx6600 PCI Express-based Integrity servers have the following limitations
in hot-plug functionality:
Hot-plug operations on PCI Express slots 3 and 4 are currently disabled.
Regarding hot-plug operations on PCI-X slots 7, 8, 9, and 10: Doorbell functionality can be
intermittent. You must press the attention button until the power indicator LED is either
solidly on or off.
Adding a PCI card
This section describes how to add a PCI card (called a hot-plug addition) on HP Integrity servers
running Windows Server 2003.
Before performing hot-plug additions or deletions to HP Integrity servers, ensure the following:
On HP Integrity rx7620, rx7640, rx8620, rx8640, and Superdome servers, you must install
the latest version of the OpRegion driver. This driver is not required on the rx4640 server.
HP Integrity rx4640 server slots 2 to 3 and 4 to 5 are shared PCI hot-plug slots. For optimal
hot-plug operation, use the same type of PCI cards in these shared slots. For example, if a
PCI-X 133 MHz card is in slot 4, the insertion of a PCI 66 MHz card in slot 5 will fail because
the slot has been set at 133 MHz. However, if a PCI-X 66 MHz card is in slot 3, the insertion
of a PCI-X 133 MHz in slot 2 will be successful, although both cards will run at 66 MHz. The
rx7620 and rx8620 do not have shared slots and are therefore not subject to these restrictions.
Ensure that the server has the latest version of the system firmware installed.
Hardware interface for all HP Integrity servers except Superdome
To perform hot-plug additions using the server hardware interface for all HP Integrity servers
except Superdome, complete the following steps:
1.
Locate an empty slot.
2.
If the power light is on for the slot, press the attention button to start the power-off sequence.
(If the power light is not on, you do not need to press the attention button.) The power LED
will blink for 5 seconds. While the power LED is flashing, you can cancel the power-off
sequence by pressing the attention button again.
72
Performing hot-plug operations