HP Kayak XU 03xx HP Kayak XU Series 03xx, User's Guide - Page 151

The External 16/8-bit Symbios BIOS and the FastRAID BIOS cannot

Page 151 highlights

4 Technical Information Using the ArrayConfig Program 4 The External 16/8-bit Symbios BIOS and the FastRAID BIOS cannot be loaded at the same time in BIOS setup. The Symbios BIOS should be disabled (from the Advanced/External and Internal Wide 16/8-bit SCSI window, disable Option ROM Scan). This may be fixed in a later version of the BIOS. Check the World Wide Web at the following site: http://www.hp.com/go/ kayaksupport/ to see if this has been corrected. Consequence: you cannot boot from devices connected to the Symbios controller at the same time as Wide SCSI devices. It is, however, possible to manually switch from bootable SCSI devices, connected to the Symbios controller, to Wide SCSI devices. 5 Ensure that you boot from the Windows NT diskettes provided and not from the CD-ROM. If you boot from the CD-ROM, the hard drive will not be found (problem relating to Windows NT). 6 Ensure that the FastRAID/Array1000 drivers are installed. To install these drivers: a Shut down your PC Workstation, remove the ARO-1130 adapter, and restart your system. b Click the Start menu, point to Settings, and then click Control Panel. c Double-click the SCSI Adapters icon, then the Drivers tab. d Click Add, Have Disk..., and insert the Adaptec Array1000 driver diskette. e When requested to enter the driver path, type A:\winnt and follow the installation instructions (the Windows NT 4.0 CD-ROM may be needed). f Shut down your computer and re-install the FastRAID card. English 135

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190

English
135
4
Technical Information
Using the ArrayConfig Program
4
The External 16/8-bit Symbios BIOS and the FastRAID BIOS cannot
be loaded at the same time in BIOS setup. The Symbios BIOS should
be disabled (from the
Advanced/External and Internal Wide
16/8-bit SCSI
window, disable
Option ROM Scan
). This may be
fixed in a later version of the BIOS. Check the World Wide Web at the
following site:
kayaksupport/
to see if this has been corrected.
Consequence: you cannot boot from devices connected to the
Symbios controller at the same time as Wide SCSI devices. It is,
however, possible to manually switch from bootable SCSI devices,
connected to the Symbios controller, to Wide SCSI devices.
5
Ensure that you boot from the Windows NT diskettes provided and
not from the CD-ROM. If you boot from the CD-ROM, the hard drive
will not be found (problem relating to Windows NT).
6
Ensure that the FastRAID/Array1000 drivers are installed. To install
these drivers:
a
Shut down your PC Workstation, remove the ARO-1130 adapter,
and restart your system.
b
Click the Start menu, point to Settings, and then click Control
Panel.
c
Double-click the SCSI Adapters icon, then the Drivers tab.
d
Click Add, Have Disk..., and insert the Adaptec Array1000 driver
diskette.
e
When requested to enter the driver path, type
A:\winnt
and
follow the installation instructions (the Windows NT 4.0 CD-ROM
may be needed).
f
Shut down your computer and re-install the FastRAID card.