HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 129
Verifying Operation of the New CP Card, from the serial console for the active CP card
![]() |
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 129 highlights
Installing SAN Director 2/128 FRUs 6. Verify that the Power LED is green (might require a few seconds). If not, ensure that the CP card has power, is firmly seated, and the ejectors are in the locked position. 7. Connect the modem, serial, and Ethernet cables as required to the new CP card. Caution: Do not route the cables in front of the air exhaust vent (located at the top of the port side of the chassis). Verifying Operation of the New CP Card 1. Verify that boot and POST are complete on the new CP card (a minimum of 3 minutes) and that the CP cards have achieved failover redundancy: a. Wait until the Status LEDs on both CP cards are off. Note: The Status LED on the active CP card displays yellow until the active CP card is fully operational, and the Status LED on the standby CP card displays yellow until the CP cards have achieved failover redundancy. b. Enable the redundancy feature by entering the haenable command from the serial console for the active CP card c. From the serial console for the active CP card (which should still be the CP card that was not replaced), enter the hashow command and verify that the command output includes "HA Enabled, Heartbeat Up, State Synchronized". swDir:admin> hashow Local CP (Slot 5, CP0): Active Remote CP (Slot 6, CP1): Standby HA Enabled, Heartbeat Up, State Synchronized swDir:admin> SAN Director 2/128 Installation Guide 129
![](/manual_guide/products/hewlettpackard-storageworks-2128-hp-storageworks-san-director-2128-installation-guide-v42x-aarvusbte-2004-deadb4a/129.png)