HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 95
WWN bezel LEDs, Table 12: WWN Bezel LED Patterns, WWN bezel LEDs, Table 12
![]() |
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
Operating the SAN Director 2/128 Port Cards (Slots 1-4 and 7-10) Power LED (upper LED) Status LED (lower LED) CP Cards (Slots 5 and 6) Power LED (upper LED) scale: 5/16" = 1" Status LED (lower LED) 1 2 3 4 5 6 7 8 9 10 pwr4 pwr3 pwr2 pwr1 Power Supplies Power LED/ Status LED 2.021 Badge Captive Screw (2x) Figure 19: WWN bezel LEDs Table 12: WWN Bezel LED Patterns LED Location/Purpose Color Status Recommended Action 16-Port card/CP card Power Steady green Power is OK. No action required. 16-Port card/CP card Status Steady amber Card is faulty. No light (LED is OFF) Card is OK. Check card. No action required. Note: If a card slot or power supply bay has a filler panel installed, the corresponding LEDs on the WWN card do not light up. Power supply Power/Status Steady green Steady amber Power is OK. No action required. Power supply is faulty. Check power supply. Note: If a Status LED on the WWN bezel flashes, the Power LED on the WWN bezel also flashes, for increased visibility. SAN Director 2/128 Installation Guide 95
![](/manual_guide/products/hewlettpackard-storageworks-2128-hp-storageworks-san-director-2128-installation-guide-v42x-aarvusbte-2004-deadb4a/95.png)