HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 94
Table 11: Messages That Can Indicate WWN Card Failure, HP StorageWorks Fabric OS 4.2.x Command
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
Operating the SAN Director 2/128 3. If the error log or serial console display error messages that indicate problems with WWN units (see Table 11), the WWN card might have failed. WWN units correspond to information specific to the WWN card and are displayed by the chassisshow command. For additional information about this command, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. Table 11: Messages That Can Indicate WWN Card Failure Type of Message WWN unit fails its FRU (field replaceable unit) header access. WWN unit is being faulted. WWN unit is not present or is not accessible. Writing to the FRU history log (hilSetFruHistory) has failed. Sample Error Message 0x24c (fabos): Switch: switchname, error EM-I2C_TIMEOUT, 2, WWN 1 I2C timed out: state 0x4 0x24c (fabos): Switch: switchname, Critical EM-WWN_UNKNOWN, 1, Unknown WWN #2 is being faulted 0x24c (fabos): Switch: switchname, Error EM-WWN_ABSENT, 2, WWN #1 not present 0x24c (fabos): Switch: switchname, Error EM-HIL_FAIL, 2, HIL Error: hilSetFruHistory failed, rc=-3 for SLOT 3 Note: For more information about error messages, refer to the HP StorageWorks Diagnostic and System Error Messages 4.2.x Reference Manual. 94 SAN Director 2/128 Installation Guide