Table 11: Messages That Can Indicate WWN Card Failure, HP StorageWorks Fabric OS 4.2.x Command

Page 94 highlights

Operating the SAN Director 2/128 3. If the error log or serial console display error messages that indicate problems with WWN units (see Table 11), the WWN card might have failed. WWN units correspond to information specific to the WWN card and are displayed by the chassisshow command. For additional information about this command, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. Table 11: Messages That Can Indicate WWN Card Failure Type of Message WWN unit fails its FRU (field replaceable unit) header access. WWN unit is being faulted. WWN unit is not present or is not accessible. Writing to the FRU history log (hilSetFruHistory) has failed. Sample Error Message 0x24c (fabos): Switch: switchname, error EM-I2C_TIMEOUT, 2, WWN 1 I2C timed out: state 0x4 0x24c (fabos): Switch: switchname, Critical EM-WWN_UNKNOWN, 1, Unknown WWN #2 is being faulted 0x24c (fabos): Switch: switchname, Error EM-WWN_ABSENT, 2, WWN #1 not present 0x24c (fabos): Switch: switchname, Error EM-HIL_FAIL, 2, HIL Error: hilSetFruHistory failed, rc=-3 for SLOT 3 Note: For more information about error messages, refer to the HP StorageWorks Diagnostic and System Error Messages 4.2.x Reference Manual. 94 SAN Director 2/128 Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202

Operating the SAN Director 2/128
94
SAN Director 2/128 Installation Guide
3.
If the error log or serial console display error messages that indicate problems
with WWN units (see
Table 11
), the WWN card might have failed.
WWN units correspond to information specific to the WWN card and are
displayed by the
chassisshow
command. For additional information about
this command, refer to the
HP StorageWorks Fabric OS 4.2.x Command
Reference Guide
.
Note:
For more information about error messages, refer to the
HP StorageWorks
Diagnostic and System Error Messages 4.2.x Reference Manual.
Table 11:
Messages That Can Indicate WWN Card Failure
Type of Message
Sample Error Message
WWN unit fails its FRU (field
replaceable unit) header access.
0x24c (fabos): Switch:
switchname
, error
EM-I2C_TIMEOUT, 2, WWN 1 I2C timed out: state 0x4
WWN unit is being faulted.
0x24c (fabos): Switch:
switchname
, Critical
EM-WWN_UNKNOWN, 1, Unknown WWN #2 is
being faulted
WWN unit is not present or is not
accessible.
0x24c (fabos): Switch:
switchname
, Error
EM-WWN_ABSENT, 2, WWN #1 not present
Writing to the FRU history log
(
hilSetFruHistory
) has failed.
0x24c (fabos): Switch:
switchname
, Error EM-HIL_FAIL, 2,
HIL Error: hilSetFruHistory failed, rc=-3 for SLOT 3