HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 82
Table 6: 16-Port Card LED Patterns, Location, Purpose, Color, Status, Recommended Action
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Operating the SAN Director 2/128 Table 6: 16-Port Card LED Patterns LED Location/ Purpose Power Color Steady green No light (LED is off) Status No light (LED is off) Steady yellow Port Speed (upper LED adjacent to each port) Slow-flashing yellow (on 2 seconds; then off 2 seconds) Fast-flashing yellow (on 1/2 second; then off 1/2 second) No light (LED is off) Steady green Status Port card receiving power. Port card is not receiving power. Port card is either healthy or does not have power. Port card is faulty. Port card is not seated correctly or is faulty. Environmental range exceeded. Port is either set to 1 Gb/sec mode, or it does not have incoming power. Port is set to 2 Gbit/sec mode. Recommended Action No action required. Ensure card is firmly seated and has power. Verify that the power LED is on. Ensure card is firmly seated and check status with slotshow command. If LED remains yellow, consult switch supplier. Pull card out and reseat it. If LED continues to flash, replace card. Check for out-of-bounds environmental condition and correct it. Verify that the power LED is on. Use portcfgspeed command to change mode. No action required. 82 SAN Director 2/128 Installation Guide