HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 86

Table 7: CP Card LED Patterns, Table 7, CP Card LED Patterns

Page 86 highlights

Operating the SAN Director 2/128 Table 7: CP Card LED Patterns LED Location/ Purpose Power Color Steady green No light (LED is off) Status No light (LED is off) Steady yellow Ethernet Link Status (upper LED beneath Ethernet port) Ethernet Link Speed (lower LED beneath Ethernet port) Active CP (beneath Ethernet Link Status and Speed LEDs) Slow-flashing yellow (on 2 seconds; then off 2 seconds) Fast-flashing yellow (on 1/2 second; then off 1/2 second) No light (LED is off) Flickering green/yellow No light (LED is off) Steady green Steady blue No light (LED is off) Status CP card is not receiving power. CP card is not receiving power. CP card is either healthy or does not have power. CP card is faulty or the switch is still booting. CP card is not seated correctly or is faulty. Environmental range exceeded. Either an Ethernet link is not detected, or it does not have incoming power. Ethernet link is healthy and traffic is flowing through port. Ethernet link speed is 10 Mb/s or CP card does not have incoming power. Ethernet link speed is 100 Mb/s. Active CP card. Standby CP card. Recommended Action No action required. Ensure card is firmly seated and has power. Verify that the power LED is on. Ensure card is firmly seated and switch has completed booting. If LED remains yellow, consult switch supplier. Pull card out and reseat it. If LED continues to flash, replace card. Check for out-of-bounds environmental condition and correct it. Ensure the card has power, Ethernet cable is firmly seated, and connected device is functioning. No action required. Ensure CP has power. Note: To force a persistent Ethernet link speed, use the ifmodeset command. No action required. No action required. No action required. 86 SAN Director 2/128 Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202

Operating the SAN Director 2/128
86
SAN Director 2/128 Installation Guide
Table 7:
CP Card LED Patterns
LED
Location/
Purpose
Color
Status
Recommended Action
Power
Steady green
CP card is not
receiving power.
No action required.
No light (LED is off)
CP card is not
receiving power.
Ensure card is firmly seated
and has power.
Status
No light (LED is off)
CP card is either
healthy or does not
have power.
Verify that the power LED is
on.
Steady yellow
CP card is faulty or
the switch is still
booting.
Ensure card is firmly seated
and switch has completed
booting. If LED remains
yellow, consult switch
supplier.
Slow-flashing yellow
(on 2 seconds; then
off 2 seconds)
CP card is not seated
correctly or is faulty.
Pull card out and reseat it. If
LED continues to flash,
replace card.
Fast-flashing yellow
(on 1/2 second; then
off 1/2 second)
Environmental range
exceeded.
Check for out-of-bounds
environmental condition and
correct it.
Ethernet Link
Status (upper
LED beneath
Ethernet port)
No light (LED is off)
Either an Ethernet link
is not detected, or it
does not have
incoming power.
Ensure the card has power,
Ethernet cable is firmly
seated, and connected
device is functioning.
Flickering
green/yellow
Ethernet link is healthy
and traffic is flowing
through port.
No action required.
Ethernet Link
Speed (lower
LED beneath
Ethernet port)
No light (LED is off)
Ethernet link speed is
10 Mb/s or CP card
does not have
incoming power.
Ensure CP has power.
Note:
To force a persistent
Ethernet link speed, use the
ifmodeset
command.
Steady green
Ethernet link speed is
100 Mb/s.
No action required.
Active CP
(beneath
Ethernet Link
Status and
Speed LEDs)
Steady blue
Active CP card.
No action required.
No light (LED is off)
Standby CP card.
No action required.