HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 40
Removing the Chassis Door, Sequence for detaching the chassis door from the hinges
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 40 highlights
Installing and Configuring the SAN Director 2/128 Removing the Chassis Door You must remove the chassis door before lifting the switch off the pallet. Use these steps to remove the chassis door. Note: To ensure adequate cooling, install the chassis with the port side facing the aisle into which exhaust air is released (usually called the "service aisle"). This prevents the fans from pulling in heated exhaust air. 1. Open the door to a 90° angle. 2. Push the spring-loaded lever on the upper hinge up and into the notch in the hinge. See Figure 4. 3. Push the spring-loaded lever on the lower hinge down and into the notch in the hinge, while supporting the door to prevent it from falling. See Figure 4 for the complete chassis door removal sequence. 1 2 Figure 4: Sequence for detaching the chassis door from the hinges 3 SHR-2508A Note: Put the chassis door aside. You will need to reinstall it after moving the SAN Director 2/128 off the pallet. 40 SAN Director 2/128 Installation Guide