HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 130

Enter the, command. The command output should show the new, CP card as enabled.

Page 130 highlights

Installing SAN Director 2/128 FRUs Note: If the command output does not include "HA Enabled, Heartbeat Up, State Synchronized", POST is not complete or the CP cards have not yet achieved redundancy. Wait a minute or two and reenter the command, until you can verify that redundancy has been achieved. 2. Enter the slotshow command. The command output should show the new CP card as "enabled". swDir:admin> slotShow Slot Blade Type ID Status 1 SW BLADE 4 FAULTY 2 SW BLADE 4 DISABLED 3 SW BLADE 4 ENABLED 4 SW BLADE 4 DIAG RUNNING POST2 5 CP BLADE 5 ENABLED 6 CP BLADE 5 ENABLED 7 UNKNOWN VACANT 8 SW BLADE 4 DIAG RUNNING POST1 9 SW BLADE 4 INSERTED, NOT POWERED ON 10 UNKNOWN VACANT swDir:admin> 3. Determine the firmware version (enter the firmwareshow command). swDir:admin> firmwareshow Primary partition: v4.2.0meteor_pit_02_031204_0722 Secondary Partition: v4.2.0meteor_pit_02_031204_0722 swDir:admin> 130 SAN Director 2/128 Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202

Installing SAN Director 2/128 FRUs
130
SAN Director 2/128 Installation Guide
Note:
If the command output does not include °HA Enabled, Heartbeat Up, State
Synchronized±, POST is not complete or the CP cards have not yet achieved
redundancy. Wait a minute or two and reenter the command, until you can verify that
redundancy has been achieved.
2.
Enter the
slotshow
command. The command output should show the new
CP card as “enabled”.
3.
Determine the firmware version (enter the
firmwareshow
command).
swDir:admin> slotShow
Slot
Blade Type
ID
Status
---------------------------------
1
SW BLADE
4 FAULTY
2
SW BLADE
4 DISABLED
3
SW BLADE
4 ENABLED
4
SW BLADE
4 DIAG RUNNING POST2
5
CP BLADE
5 ENABLED
6
CP BLADE
5 ENABLED
7
UNKNOWN
VACANT
8
SW BLADE
4 DIAG RUNNING POST1
9
SW BLADE
4 INSERTED, NOT POWERED ON
10
UNKNOWN
VACANT
swDir:admin>
swDir:admin> firmwareshow
Primary partition:
v4.2.0meteor_pit_02_031204_0722
Secondary Partition:
v4.2.0meteor_pit_02_031204_0722
swDir:admin>