HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 130
Enter the, command. The command output should show the new, CP card as enabled.
![]() |
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 130 highlights
Installing SAN Director 2/128 FRUs Note: If the command output does not include "HA Enabled, Heartbeat Up, State Synchronized", POST is not complete or the CP cards have not yet achieved redundancy. Wait a minute or two and reenter the command, until you can verify that redundancy has been achieved. 2. Enter the slotshow command. The command output should show the new CP card as "enabled". swDir:admin> slotShow Slot Blade Type ID Status 1 SW BLADE 4 FAULTY 2 SW BLADE 4 DISABLED 3 SW BLADE 4 ENABLED 4 SW BLADE 4 DIAG RUNNING POST2 5 CP BLADE 5 ENABLED 6 CP BLADE 5 ENABLED 7 UNKNOWN VACANT 8 SW BLADE 4 DIAG RUNNING POST1 9 SW BLADE 4 INSERTED, NOT POWERED ON 10 UNKNOWN VACANT swDir:admin> 3. Determine the firmware version (enter the firmwareshow command). swDir:admin> firmwareshow Primary partition: v4.2.0meteor_pit_02_031204_0722 Secondary Partition: v4.2.0meteor_pit_02_031204_0722 swDir:admin> 130 SAN Director 2/128 Installation Guide
![](/manual_guide/products/hewlettpackard-storageworks-2128-hp-storageworks-san-director-2128-installation-guide-v42x-aarvusbte-2004-deadb4a/130.png)