HP StorageWorks 2/128 HP StorageWorks SAN Director 2/128 Installation Guide, V - Page 97
Obtaining Chassis and Component Status, Table 13: Environmental Status and Maintenance Commands
View all HP StorageWorks 2/128 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
Operating the SAN Director 2/128 Obtaining Chassis and Component Status The CLI commands listed in Table 13 provide status and environmental information about the chassis and its components. These commands provide information only, and they do not interrupt traffic flow. For more information about these commands, refer to the HP StorageWorks Fabric OS 4.2.x Command Reference Guide. Note: The environmental commands report internal temperatures within the chassis. The 16-port cards can withstand internal temperatures of up to 75oC and the CP cards can continue to operate up to 80oC. However, the ambient temperature outside the chassis must be 40oC or less. Table 13: Environmental Status and Maintenance Commands Command sensorshow tempshow psshow fanshow Information Displayed Temperature readings for the port cards Temperature readings for the CP cards Status and RPM of all operational fans Status of all operational power supplies Temperature readings for the port cards Temperature readings for the CP cards Status of all operational power supplies Status and RPM of all operational fans chassisshow Serial number, time awake, and additional information about each component slotshow Slot occupancy errshow Switch error log (lists status of any marginal/failed components) Note: Enter CLI commands with all lowercase characters. SAN Director 2/128 Installation Guide 97