HP Surestore Tape Library Model 6/140 HP SureStore E Tape Library Model 6/140 - Page 116

Based Library Administrator, Removing/Replacing

Page 116 highlights

Understanding Errors and Troubleshooting Understanding Error States Table 4-1 Partial Availability Conditions Library Status Cause Solution Drive critical error Drive not on Fibre Channel Firmware update needed Library fan failure Magazines missing Door open A critical error occurred on a drive. • Check the Drive Event Log from the front panel or RMC WebBased Library Administrator pages for possible causes. • Contact your service representative. Drive(s) are detected by library controller but are not detected by any of the Fibre Channel interfaces. • Verify that this is your intended configuration. • Verify that there are no broken or bent pins on the SCSI cables. • Tighten all SCSI cables and power cycle the library. • If problem persists, replace the SCSI cables. • Contact your service representative. A library component has firmware that is different from the rest of the library. • Update library firmware. (See page 4-60.) A library card cage fan has failed. • Power cycle the library. • Contact your service representative. Library could not detect all the magazines. • Ensure that all magazines are present and correctly installed. (See "Removing/Replacing a Magazine" on page 2-12.) One or more tape doors are • Ensure that doors are closed. open. The library robotics will not move until the door is closed. 4-10 Chapter 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240

Understanding Errors and Troubleshooting
Understanding Error States
Chapter 4
4-10
Drive critical
error
A critical error occurred on a
drive.
Check the
Drive Event Log
from
the front panel or RMC Web-
Based Library Administrator
pages for possible causes.
Contact your service
representative.
Drive not on Fibre
Channel
Drive(s) are detected by library
controller but are not detected
by any of the Fibre Channel
interfaces.
Verify that this is your
intended configuration.
Verify that there are no broken
or bent pins on the SCSI cables.
Tighten all SCSI cables and
power cycle the library.
If problem persists, replace the
SCSI cables.
Contact your service
representative.
Firmware update
needed
A library component has
firmware that is different from
the rest of the library.
Update library firmware.
(See page 4-60.)
Library fan
failure
A library card cage fan has
failed.
Power cycle the library.
Contact your service
representative.
Magazines
missing
Library could not detect all the
magazines.
Ensure that all magazines are
present and correctly installed.
(See
Removing/Replacing a
Magazine
on page 2-12.)
Door open
One or more tape doors are
open. The library robotics will
not move until the door is closed.
Ensure that doors are closed.
Table 4-1
Partial Availability Conditions
Library Status
Cause
Solution