HP Surestore Tape Library Model 6/140 HP SureStore E Tape Library Model 6/140 - Page 118
Fibre Channel, redundant power supplies in
View all HP Surestore Tape Library Model 6/140 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Understanding Errors and Troubleshooting Understanding Error States Table 4-1 Partial Availability Conditions Library Status Cause Solution Fibre Channel interface failed Power supply fault Fibre Channel interface failed power-up test. (Usually due to problems on the SCSI bus, such as an LVDS drive or terminator on an HVDS bus, etc.) Library detected one or more redundant power supplies in a failed condition. • Verify that proper SCSI terminators and/or tape drives are attached to the Fibre Channel interface, and then reboot the library. • Power cycle the library. • Contact your service representative. • Determine which power supply has failed. See page 4-27 for LED status information. • Contact your service representative to replace the power supply. 4-12 Chapter 4